Drive Belt Adjustment
See picture # 6 (below)
1. Remove three (3) phillips head screws holding the pad center grip.
2. Remove four (4) large, slot head screws holding drive pad.
3. Loosen pulley mount bolts
(A)
with 9/16" deep socket wrench.
Do not
remove the bolts.
4. Using a 1/2 box wrench, turn adjustment nut
(B)
until it touches the adjust-
ment bolt head. Turn the adjustment bolt to tighten or loosen the belt tension.
5. Correct belt tension allows belt
(C)
no more than 1/4" of side movement.
6. Tighten the four (4) pulley mount bolts with the 9/16” socket wrench.
7. Loosen the adjusting bolt
(D)
until it is snug against adjustment stop molded
in housing and turn adjustment nut against pulley mount bracket.
8. Replace pad driver and pad center grip.
TROUBLESHOOTING
Burnisher tends to move to the right.
• Do not lift up on handle while operating the burnisher.
• Do not operate with handle set too high. Recommended handle height is from
your waist with your arms extended forward.
Burnisher does not run.
• Circuit breaker has tripped. Allow circuit breaker to cool two minutes before
resetting (P1200 only).
Prevent circuit overload.
• Do not spray buff with the P1600 or P2000. Apply a restorer, such as Powr-
Gloss®, allow to dry, then burnish.
• Check pad and change if dirty or rough.
• Check area being burnished for cleanliness, area should be damp mopped,
scrubbed or swept with treated broom.
• Operator should not continually force the machine with handle pressure.
• Operator should not try to operate burnisher in a side-to-side motion.
• Eliminate any extension cord that is smaller than 12/3 wire or greater than 25
feet in length.
Burnisher will not start.
• Circuit breaker is not reset. Allow two minutes to cool. Reset breaker.
(P1200 only)
• Plug is broken or has loose contact. Replace.
• Circuit breaker is defective or weak. Replace. (P1200 only)
• Switch is defective. Replace switch.
• Rectifier is defective. Replace.
A
A
A
A
B
B
B
B
D
D
D
D
C
C
C
C
X8442
SAFETY INSTRUCTIONS
This Floor Machine should be grounded while in use to protect the operator
from electric shock. This machine is equipped with a 3-conductor cord and a 3-
prong grounded type attachment cap plug to fit the proper grounding type
receptacle. The green (or green and yellow) conductor in the cord is the ground-
ing wire. Never connect this wire to anything other than the grounding blade.
The Floor machine is provided with an attachment cap plug, as shown in
Sketch A, and is intended for use on a nominal 120 volt circuit. If a properly
grounded receptacle, as shown in Sketch A, is unavailable, an adaptor, as shown
in Sketch C, is available and should be installed, as shown in Sketch B, if the out-
let box that houses the receptacle is grounded. Be sure to fasten the grounding tap
to the faceplate screw.
These guidelines are presented for your protection and convenience. Please
read them carefully, since a failure to heed these precautions could result in dis-
comfort or injury. When using an electrical appliance, basic safety precautions
should always be followed.
ONE LAST REMINDER!
Read All Instructions, Warnings and Cautions Before Using!
WARNING
TO AVOID FIRE, DO NOT USE WITH A FLAMMABLE OR
COMBUSTIBLE LIQUID TO CLEAN FLOOR.
© 2000 Tacony, Inc, All Rights Reserved
A Tacony Company
3101 Wichita Court • Ft. Worth, TX 76140-1710