8

Storage of Equipment

1.  Store extractor indoors in a dry area.

2.  Recovery and solution tank should be empty and clean when the extractor is not in use.

3.  Leave the recovery lid and drain hose open to air out the recovery tank.

4.  Do not store in freezing temperature.

5.  A small amount of windshield washer fluid may be left in the pump and internal solution line 

for protection against freezing.

Warnings

1.  Do not break off or pull the grounding prong on the plug.

2.  Do not attempt repair on a machine that is under warranty unless instructions to perform it 

by an authorized shop are obtained from the factory.

3.  Do not use citrus-based (D-Limonene) cleaners in this  machine.

4.  Do not use cleaning chemicals in this machine except  those recommended for steam-type 

extraction equipment. The use of any chemicals with abrasive additives voids the 

 warranty.

5.  Do not use any replacement parts except those specified on the parts list.  Performance of 

the machine could be affected if substitutions are made.

6.  Do not use water in excess of 140° F (60° C) through the pump system. It could damage the 

seals and polyprophene casing of the diaphragm pump.

7.  Follow maintenance schedule strictly.

8.  Failure to comply with the above warnings instructions will void the warranty.

Fig. 4

Содержание PE310-G10-U

Страница 1: ...Pulsar Delta Extractor Pulsar Delta Extractor OPERATOR S MANUAL PE310 G10 U PE310 G15 U...

Страница 2: ...2 CONTENTS Introduction 3 Warranty 3 Grounding Instructions 4 Important Safety Instructions 5 General Instructions 6 Maintenance 7 Storage of Equipment 8 Troubleshooting Information 9...

Страница 3: ...t it for any other use Modification of this unit in any way will void all warranties and could create safety hazards Your new Powr Flite unit is a high quality precision made product All parts used in...

Страница 4: ...codes and ordinances This appliance is for use on a nominal 115 volt circuit and has a grounding plug that looks like the plug illustrated in sketch A A DANGER Improper use of the grounding plug can r...

Страница 5: ...with any opening blocked keep free of dust lint hair or anything that may reduce air flow 7 Keep hair loose clothing fingers and all parts of body away from openings and moving parts 8 DO NOT pick up...

Страница 6: ...e pump switch 1 Fig 3 to the ON position 8 With the solution line attached to the wand and the machine prime the pump by squeezing the trigger on the wand releasing the water hold wand tip over soluti...

Страница 7: ...r A white vinegar solution may also be used This will counter act hard water and alkaline deposits and aid in keeping orifices clean 4 Do not allow fluid either in solution or recovery tank to sit ove...

Страница 8: ...nstructions to perform it by an authorized shop are obtained from the factory 3 Do not use citrus based D Limonene cleaners in this machine 4 Do not use cleaning chemicals in this machine except those...

Страница 9: ...nk lid 5 Loose hose connection 6 Vacuum motor exhaust blocked 1 Close drain hose 2 Repair or replace hose 3 Open machine connect vacuum hose to recovery tank 4 Replace tank lid Recovery tank lid must...

Страница 10: ...and any other foreign material from screen 2 Remove and clean Leaking or stuck solution valve 1 Foreign material in valve 2 Loose brass hex nut 3 Valve or seals worn 1 Remove brass hex plug clean val...

Страница 11: ...11 NOTES...

Страница 12: ...12 Powr Flite 3101 Wichita Court Ft Worth TX 76140 1755 Phone 817 551 0700 WWW POWR FLITE COM P OMPE310 08 2021 Record of Purchase Serial Number Purchase Date Dealer Phone Number...

Отзывы: