To receive reliable service from this equipment, regular daily maintenance is a requirement. 
Fabric cleaning, both carpet and upholstery, are very dirty environments for any equipment.  The 
following recommendations are offered.

1. Keep the equipment clean, both inside and out.

2. Lubricate brass quick disconnects with a quality lubricant such as WD-40®.

3. Flush solution systems after use with clear, clean water.  A white vinegar solution may also be 
used. This will counter-act hard water and alkaline deposits and aid in keeping orifices clean.

4. Do not allow fluid either in solution or recovery tank to sit overnight. The unit should be 
emptied and cleaned daily.

5. Clean the strainer in the solution tank (Fig. 4) daily.

6. Do not use the same receptacle (pail) to fill solution tank that has been used to remove waste 
water from recovery tank.

7. When the unit is not in use, leave the tank lids open.

8. At the end of each day, run the vacuum for 3 minutes with lid open.

Maintenance

Fig. 2

Fig. 3

1

1

22

33

44

55

66

88

99

77

Содержание PE310-G10-U

Страница 1: ...Pulsar Delta Extractor Pulsar Delta Extractor OPERATOR S MANUAL PE310 G10 U PE310 G15 U...

Страница 2: ...2 CONTENTS Introduction 3 Warranty 3 Grounding Instructions 4 Important Safety Instructions 5 General Instructions 6 Maintenance 7 Storage of Equipment 8 Troubleshooting Information 9...

Страница 3: ...t it for any other use Modification of this unit in any way will void all warranties and could create safety hazards Your new Powr Flite unit is a high quality precision made product All parts used in...

Страница 4: ...codes and ordinances This appliance is for use on a nominal 115 volt circuit and has a grounding plug that looks like the plug illustrated in sketch A A DANGER Improper use of the grounding plug can r...

Страница 5: ...with any opening blocked keep free of dust lint hair or anything that may reduce air flow 7 Keep hair loose clothing fingers and all parts of body away from openings and moving parts 8 DO NOT pick up...

Страница 6: ...e pump switch 1 Fig 3 to the ON position 8 With the solution line attached to the wand and the machine prime the pump by squeezing the trigger on the wand releasing the water hold wand tip over soluti...

Страница 7: ...r A white vinegar solution may also be used This will counter act hard water and alkaline deposits and aid in keeping orifices clean 4 Do not allow fluid either in solution or recovery tank to sit ove...

Страница 8: ...nstructions to perform it by an authorized shop are obtained from the factory 3 Do not use citrus based D Limonene cleaners in this machine 4 Do not use cleaning chemicals in this machine except those...

Страница 9: ...nk lid 5 Loose hose connection 6 Vacuum motor exhaust blocked 1 Close drain hose 2 Repair or replace hose 3 Open machine connect vacuum hose to recovery tank 4 Replace tank lid Recovery tank lid must...

Страница 10: ...and any other foreign material from screen 2 Remove and clean Leaking or stuck solution valve 1 Foreign material in valve 2 Loose brass hex nut 3 Valve or seals worn 1 Remove brass hex plug clean val...

Страница 11: ...11 NOTES...

Страница 12: ...12 Powr Flite 3101 Wichita Court Ft Worth TX 76140 1755 Phone 817 551 0700 WWW POWR FLITE COM P OMPE310 08 2021 Record of Purchase Serial Number Purchase Date Dealer Phone Number...

Отзывы: