External Alarms
The OS booster is capable of monitoring and reporting external Form-C alarms. Four channels are provided
and each channel is programmed via the Controller Module for NO or NC conditions. For example, NO will
fault when shorted to Common (C) and NC will fault when open to Common (C).The four channels are mapped
to Form-C alarm outputs configured as such via the Ethernet web pages.
(1) Could be critical and bypass if both Rx channels are faulted.
(2) If enabled.
Table 1-1 Faults
Control Module Display
X =
Form-C
Fan XX Fault
FT(front)/
RT(frear)
Minor
RFCU Fault (3)
Sector 1 - 3
Critical
Bypassx DC Fault (3)
Sector 1 - 3
Critical
LNA 1 Fault
LNA 2 Fault
Sector 1 - 3
Major (1)
Rect Comm Fault
Minor
Rect VAC High
Major
Rect VAC Low
Major
Rect VDC High
Major
Rect VDC Low
Major
Rect Current Limit
Major
Rect Fault (not all)
Major
Rect Fault (all)
Critical
No MCPA
Sector 1 - 3
Critical
MCPAX VSWR
Sector 1 - 3
Critical
MCPAX Loop
Sector 1 - 3
Critical
MCPAX Ovr Pwr
Sector 1 - 3
Critical
MCPAX Hi Temp
Sector 1 - 3
Critical
MCPAXInt DC
Sector 1 - 3
Critical
MCPAX Ext DC
Sector 1 - 3
Critical
Ext Alarm0
Major (2)
Ext Alarm1
Major (2)
Ext Alarm2
Major (2)
Ext Alarm3
Major (2)
TMA1 Hi Current
Major (1)
TMA 1 Lo Current
Major (1)
TMA 2 Hi Current
Major (1)
TMA 2 Lo Current
Major (1)
Содержание OS-1933-E0-003
Страница 4: ...OS 1933 E3 003 Revision Record ii 044 05243 Rev A This page intentionally left blank...
Страница 6: ...Safety OS 1933 E3 003 viii 044 05243 Rev A This page intentionally left blank...
Страница 18: ...OS 1933 E3 003 Scope of Manual 1 8 044 05243 Rev A This page intentionally left blank...
Страница 28: ...OS 1933 E3 003 Installation Instructions 2 10 044 05243 Rev A This page intentionally left blank...