9
O
P
E
R
A T
I
N
G
I
N
S
T
R U
C
T
I
O
N
GB
must be 6A and the maximum differential current must not exceed 30mA.
The pump must not be functioning or be connected to the mains, when in the reservoir in which it is meant to be used are people
or animals.
The surroundings of the basket of the pump must be clean, so as to avoid any blockage of the inlet suction conduits.
During the operation the upper surface of the pump must be submerged at least 7 cm below the surface of water. If the water level
drops below this value, then the float switch automatically deactivates the device.
The pump may be hanged only by the holder provided for this purpose.
The pump may remain on the bottom of the reservoir, provided it is on a flat surface.
If the pump is being operated in a well, the minimum dimensions of the well must be (40 x 40 x 50) cm.
Before any maintenance or current service of the pump, it is required to remove the plug of the cable of the pump from the mains
socket.
The device must not be operated by children or persons whose physical, sensorial and psychological capacities are reduced, or
by persons lacking the required experience and knowledge, unless they are supervised or have been trained. Supervise children
and make sure they do not use the device as a toy.
OPERATION OF THE PUMP
OBS
Ł
UGA POMPY
Starting the pump
Assembly the pump, submerse in water reservoir. Be sure, that the body of pump is completely under the water surface. The pump
is not equipped in any power switch, it starts immediately after the connection to the power supply.
MAINTENANCE OF THE PUMP
Before carrying out any maintenance work, disconnect the pump from the electrical outlet.
The pump does not require any special maintenance. The pump housing should be cleaned with clean water. It should also
ensure that the water in the reservoir, in which the pump is to work was clean and the pump must always be situated below the
water surface.
Failure
Possible cause
Solution
Pump doesn’t work
Lack of power supply
Check the power supply connection
Clogged water inlet
Check that the inlet slots are not clogged by dirt
Damage to the pump
Contact a special repair service
Water flows uneven stream
Water level in the reservoir is too low
Check is the pump body submerged at least 0.5 m below the water surface, top up if
necessary the water in the reservoir
Increase of the pump noise during
operation
Damage to the pump
Contact a special repair service
ENVIRONMENTAL PROTECTION
Correct disposal of this product: This marking shown on the product and its literature indicates this kind of product mustn’t be disposed with household wastes at the end of
its working life in order to prevent possible harm to the environment or human health. Therefore the customers is invited to supply to the correct disposal, differentiating this
product from other types of refusals and recycle it in responsible way, in order to re - use this components. The customer therefore is invited to contact the local supplier office