16
PN
: battery voltage to restart the inverter on DC mode
13.8V default, (Single: 12.6V, 12.8V, 13.0V, 13.2V, 13.4V,
13.6V, 13.8V, 14.0V, 14.2V, 14.4V, can be set)
F3
: Generator mode setting:
Default OFF (ON work with Gen. \ OFF
doesn’t work with Gen. )
F4
: Unattended mode battery lowest voltage to power
off power the inverter’s MCU.
Default single section 8.0V (8.0V, 8.2V, 8.5V, 8.7V,
8.9V, 9.0V, 9.2V, 9.5V can be set)
F5
: Fan failure detection settings:
Default single block OFF (ON, OFF)
F9
: Auto restart from Overload condition: ON
or OFF. The default is OFF.
Allows the inverter to restart automatically
after an Overload condition was detected.
The process will repeat 3 times then the
Inverter goes OFF.