4 INSTRUCTIONS PW220/PW230
1.3.1 PW220/PW230 Electromechanical Gear Motors
1.3.2 PC160 Control Box
1.3.3 PH-1 Photocells
Figure 3
1)PW220
2)PW230
3)Release Key
Figure 4
Table 2: List of small parts for PC160
Quantity
5*30 Screw
4pcs
Nylon screw anchor
4pcs
Figure 5
The pair of PH-1 photocells has to be installed on the wall and
connected to the control panel. The function of the photocells
is to detect the obstacles found on the optical axis between the
transmitter (TX) and the receiver (RX).
PC160 control box consists of one control panel with incorporated receiver,
one transformer and two back-up batteries.
PC160 provides the complete automation of the gear motors and other
accessories of PW220/PW230 kit.
To connect separate terminals on the control panel and activate the gear
motors and other accessories, the installation manual has to be carefully read
beforehand.
PW220/PW230 consists of a worm screw reduction gear and a 24V
direct current motor. The gear motor could be released manually by
special release keys when there is a power failure.
The gear motor is installed with two post brackets, one rear plate and
one front plate for the installation.
Table 1: List of small parts
PW220
PW230
Front plate
2pcs
2pcs
Rear plate
2pcs
2pcs
Post bracket
4pcs
4pcs
M8*25L hex bolt
4pcs
4pcs
M8 self-locking nut
4pcs
4pcs
M12 *25L hex bolt
0
2pcs
M12 self-locking nut
2pcs
2pcs
Release key
2pcs
2pcs
Front
Rear
Содержание PW220
Страница 1: ......
Страница 21: ...20 INSTRUCTIONS PW220 PW230 Figure 2 3 8 4 ...