background image

 INSTRUCTIONS PL600H/PL1000H

8

Figure 13

Figure 14

 (Left opening)

Figure 15

 (Right opening).

Figure 16

Gate with rack: the distances indicated in 

Figure 13

.

10) To install the limit switch brackets, the rack must project from the axis of the pinion by distances indicated in 

     Figure 14

 (Left opening) and 

Figure 15

 (Right opening).

11) If the rack is already installed on the gate, make sure the position of the rack is fitted for the size limits indicated in 

     Figure16

.

DX

SX

50mm

50mm

10mm

10mm

170mm

200mm

170mm

200mm

86-88mm

Содержание PL1000H

Страница 1: ...FOR RESIDENTIAL USER MANUAL SLIDING GATE OPENERS PL600H PL1000H 24V DC MOTOR ...

Страница 2: ......

Страница 3: ...on Gates without Rack 9 3 3 1 2 Installing on Gates with Rack 11 3 3 2 PH 2 Photocells 12 3 3 3 PF 1 Flashing Light 13 3 3 4 PKS 1 Key selector 14 3 3 5 PPB 1 Push Button 15 3 3 6 Installation of Green Box 15 3 4 Power Supply Connections 16 4 Final Checks and Start Up 16 4 1 Initial Checks 16 4 1 1 Design of PL600H PL1000H control unit 16 4 1 2 Recognition of LED Indication 17 4 1 3 Checking the G...

Страница 4: ...s works properly before installing the gate automated system and confirm the gates are appropriate for the application Do not let children operate or play with the gate automated system Do not cross the path of the gate automated system when operating Please keep all the control devices and any other pulse generator away from children to avoid the gate automated system being activated accidentally...

Страница 5: ...on of Devices H I G F C C E H 516 A A B C D E PL600H PL1000H may include the accessories shown in Figure 2 Please check the accessories the same as the package provided Attention Some accessories of PL600H PL1000H are not included due to local regulations or customized order A 1 PL600H PL1000H electromechanically gearmotor including control unit B 2 release keys C 1 pair of PH 2 photocells D 2 PR ...

Страница 6: ...it has a back up battery optional which can be used during the power failure as well 2 3 2 Release Keys The two keys enable the gearmotor to be released when there is power failure Figure 3 Figure 4 516 Green Box Fuse knob Terminals for devices RF leaning button Digital led display Function setting buttons Back up batteries optional A B E D C F G 2 3 2 1 Release Gearmotor 1 Slide the lock cover di...

Страница 7: ...he receiver RX 2 3 4 PR 1 Radio Transmitter PR 1 radio transmitter is used for the remote control of the gate movement To use the transmitter press and hold the button for 1 second There are two buttons on the transmitter and A button is open stop close mode and B button is pedestrian mode 2 3 5 PF 1 Flashing Light PF 1 flashing light is controlled by PL600H PL1000H control unit and blinks when th...

Страница 8: ... accessories and quantities installed No wiring cables for accessories are supplied with KIT PL600H PL1000H 3 Installation 3 1 2 Motors Components and Its Installation in Illustration The users are advised to read the installation manual carefully before going for it After getting to know all accessories and their positions suggest starting from cable conduit arrangement to prevent the cables from...

Страница 9: ...cifications do not meet the requirements 2 Make sure the gate structure conform to the criteria of automatic operation and force regulations 3 Make sure there is no serious friction existing in the opening or closing travel of the gate 4 Make sure the gate is at horizontal level that the gate will not move aside at any position 5 Make sure the gate can bear the impact of the motor torque when it i...

Страница 10: ...o install the limit switch brackets the rack must project from the axis of the pinion by distances indicated in Figure 14 Left opening and Figure 15 Right opening 11 If the rack is already installed on the gate make sure the position of the rack is fitted for the size limits indicated in Figure16 DX SX 50mm 50mm 10mm 10mm 170mm 200mm 170mm 200mm 86 88mm ...

Страница 11: ...it the two bent bins as below part in Figure 18 into the foundation and fix them above and below with two nuts as below part in Figure 18 make sure the outstanding part does not exceed the maximum height as Figure 18 4 Put the foundation plate and make sure the gate keeping the distances shown as Figure 12 5 Fit the conduits through the hole of the foundation plate 6 Pour the concrete 7 Sink the p...

Страница 12: ...eces of the rack until the racks are sufficient for work 15 After fixing the last piece cut away the unnecessary parts of racks by a hacksaw if necessary 16 Open and close the gate several times manually and make sure that the rack goes with the pinion smoothly within a maximum tolerance of 5mm 17 Fix the two limit switch brackets with the relative dowels as the part in Figure 23 Slide the gate in...

Страница 13: ...d leave 30 50 cm longer as Figure 24 3 Fit the two bent bins as below part in Figure 25 into the foundation and fix them above and below with two nuts as the part in Figure 25 make sure the outstanding part does not exceed the maximum height 25 35 mm as Figure 25 B C D A Figure 24 Figure 26 Figure 27 Figure 28 Figure 25 3 3 1 2 Installing on Gates with Rack 4 Put the foundation plate and make sure...

Страница 14: ...um tolerance of 5mm 15 Fix the two limit switch brackets with the relative dowels as the part in Figure 30 Slide the gate in the open position keeping at least 2 3 cm from the limit switch And then slide the bracket along the rack in the opening direction until the limit switch cuts in The brackets should be located at a sufficient distance from mechanical stops in order to keep the gate from cras...

Страница 15: ... GND and Ph1 on the PC600 PCB And use an extra wire to connect terminals 2 and 5 on the receiver as a bridge Detection Method Sensing Range Input Voltage Response Time Emitting Element Operation Indicator Dimensions Output Method Current Consumption Max Water Proof Through Beam 25M AC DC 12 24V 100MS IR LED Red LED RX ON When Beam is Broken Green TX ON 96 45 43mm Relay Output TX 35MA Rx 38MA When ...

Страница 16: ...ee Figure 3 3 4 1 2 Remove the round cover A by prizing it out with a screwdriver See Figure 3 3 4 2 3 Unscrew the two screws beside the lock body See Figure 3 3 4 3 4 Turn the key and separate the bottom of the shell with the lock body See Figure 3 3 4 4 5 Connect the four wires of the light and the antenna to the PCB terminals and place the wires into the conduit if necessary See Figure 3 3 3 5 ...

Страница 17: ...rt the shell on the bottom Turn the key back to the center position and the shell will be fixed to the bottom 9 Tighten the lock body with the two screws and insert the round cover by pressing it to attach to the whole unit Figure 3 3 4 5 Figure 3 3 5 1 Figure 3 3 5 2 Figure 3 3 5 3 Figure 3 3 4 6 A OFF ON Green Box 5 Cable AC out AC in Green Box is for purpose when gate opener is in standby mode ...

Страница 18: ...he power supply before the installation is done 2 Make sure all the wires are firmly connected 3 Supply the gearmotor with the power If the Led display is in normal performing refer to 4 2 1 you can control the gate by either transmitters or the button on the board UP clockwise moving SET stop and DOWN Counterclockwise moving 6 6 7 3 4 9 6 8 9 9 6 9 10 11 LED1 Photocells LED2 Photocells LED3 RF Le...

Страница 19: ... are activated LED2 will be on when the second pair of the photocells are activated LED3 will be on when RF learn button is pressed LED Indication Descriptions 4 1 2 Recognition of LED 4 1 3 Checking the Gate Movements 1 Release the gearmotor with the release key and move the gate to the middle so that it is free to move in both opening and closing directions then lock the gearmotor 2 Perform the ...

Страница 20: ...s 80 seconds 120 seconds 180 seconds Please the function setting afterF8 Operation 50 Study Speed 25 Middle operation 50 Operation 70 Study Speed 35 Middle operation 60 Operation 85 Study Speed 43 Middle operation 70 Operation 100 Study Speed 50 Middle operation 80 75 of full distance 80 85 90 95 80 60 40 25 10 2A 3A 4A 5A 6A 7A 8A 10A 1 The function can adjust the direction of gate opening 2 The ...

Страница 21: ...gate starts to move The flashing light blinks 3 seconds before the gate starts to move Stop Reverse 1 second Reverse 3 second Reverse to the end No function in transmitter B key C key D key No function in transmitter B key C key D key No function in transmitter B key C key D key Close Open Close Open Close Open Close Open 1 The function can adjust the time of opening partially 2 The factory settin...

Страница 22: ...Reloads automatic closing time Logic F3 2 The reactions of the safety edge photocell when detecting obstacles Gate Status Closed Open Stop during moving Closing Opening Loop Detector Open Open Open Open Photocell 1 No effect Reloads automatic closing time Open No effect Reloads automatic closing time Logic F3 3 The reactions of the loop detector photocell when detecting obstacles LED Display Progr...

Страница 23: ...le after complete F1 0 setting You would continue setting F2 5 please press SET to return the formal option The LED display shows the first two numbers as as the first option as the right hand side picture F1 And then follow the operation and 2 3 until you get F2 5 as the right hand side picture F2 5 is set completely After setting all functions you need then wait for 10seconds the LED will displa...

Страница 24: ...ly stop during moving The gearmotor does not run and the relay is noisy when operating the gate opening and closing Check the wiring connection of the batteries Check to see if the batteries are run out if necessary replace them Check to see if the transmitter has been memorized correctly with the radio receiver Check the power cord is plugged into the electricity socket Check to see if the fuses ...

Страница 25: ...ration 1 2A each 1 1kg 11 4A 22V 433 92MHz 200 transmitters memory PL600H PL1000H 8 2 PH 2 Photocells Detection type Operating distance Response time Input voltage Operating Temperature Protection class Dimension Through beam 25 meters 100ms AC DC 12 24V 20 60 IP54 96mm 45mm 43mm 8 3 PR 1 Radio Transmitter Application Frequency Coding Buttons Power Supply Operating Temperature Dimension PL600H PL1...

Страница 26: ...ove product has been tasted for CE marking according to the following European Directives 2006 42 EC Machinery Directive Comply with the following Standards EN 301489 1 V1 8 1 2008 EN 301489 3 V1 4 1 2002 EN 300220 1 V2 1 1 2006 EN 300220 2 V2 1 2 2007 EN 60335 1 2002 A11 2004 A1 2004 A12 2006 A2 2006 A13 2008 EN 60335 2 103 2003 EN 62233 2008 EN 12445 2001 EN 12453 2001 And also declare that the ...

Страница 27: ......

Страница 28: ...34100 065 02 C Powertech Automation Inc ...