Figure 6 Adjustable parameters in Setting Mode
3.4.2 Select the auto- equalization charging and night-light mode
The dip switch 1 is for Night-Light Mode , switch 2 for Equalization Charging mode and switch
3 is always set at off position
THE PV CHARGE CONTROLLER IS FACTORY PRESET FOR USE WITH SEAL TYPE BATTERY
THAT IS : NO AUTO EQUILIZATION CHARGING BECAUSE DIP SWITCH 2 IS AT ON POSITION.
* Equalization(Eq.) charging is only for wet-type Lead Acid Battery
When Auto-Equalization Charging is set at ON mode , Equalization charge will occur for
2 hours once every thirty days.
Use the dip switch to select equalization charging and night-light mode as below:
AUTO
Equalization
Charging*
Night-Light Mode
Dip Switch Settings
OFF
OFF
Dip switch 1
– OFF
Dip switch 2 –
ON
Dip switch 3 - OFF
OFF
ON
Dip switch 1 –
ON
Dip switch 2 –
ON
Dip switch 3 - OFF
ON
OFF
Dip switch 1 –
OFF
Dip switch 2
– OFF
Dip switch 3 - OFF
ON
ON
Dip switch 1 –
ON
Dip switch 2 –
OFF
Dip switch 3 - OFF
Table 4 Dip Switch Functions
Factory
Preset
P.6