25
Problem
Causes
Remedy
Auger System
Auger belt broken,
or repeated failure
Auger tension pulley arm return spring
broken or missing
Replace tension arm return spring
Auger tension pulley arm stuck or binding
Repair or replace tension arm as necessary
Auger tension pulley arm or pulley
misaligned or damaged
Repair, replace or align tension arm and or pulley
as necessary
Foreign material on pulleys and belt, oil,
grease, dirt etc.
Clean belt and pulleys as necessary, replace belt if
necessary
Auger pulleys misaligned, loose, damaged
or bent
Replace or align pulleys as necessary
Incorrect or damaged auger belt
Replace with correct size and type belt
Auger belt guide pin not adjusted
Adjust belt guide pin to within 1/8 to 3/16 in. from
pulley. (Guide pin keeps belt in pulley when
disengaged)
Auger rotating
when
auger control
handle released
Auger tension pulley arm return spring
broken or missing
Replace tension arm return spring