PROBLEM
POSSIBLE CAUSE
SOLUTION
1
Air leaking
between ex-
haust cover
and body
1. Screw loose.
Tighten screws (Part #1)
2. Damaged seal.
Check and replace seal (Part #3)
2
Air leaking in
area of
airplug
1. Air plug loose
Tighten air plug (Part #21)
2. Thread of air plug is not matched to
female screw of body.
Check and replace air plug (Part #21-n/a)
3
Air leaking in
area of top
and/or bot-
tom of body
1. Worn O-ring in cylinder/body/side/
sleeve/piston assembly.
Replace O-ring (Part #A01-In Seal Kit)
4
Tool does
not perform
properly in
exesive cold.
1. Seals and lubricant are not up to
operating temperature
Warm tool up so lubricant and seals will
allow to to function correctly.
Troubleshooting and repairs should be carried out only by trained service
personel in the field of fastener driving tools who will observe proper safety
controls while performing maintenace. Service personel should be qualified
and able to determine the safe working condition of fastener driving tools.
Free technical support, contact
Powernail USA at 800-323-1653 or 847-847-3016
9
TROUBLESHOOTING
For Step-by-Step Videos and Instructions,
Visit our Web Site at: www.Powernail.com