7
NAILER SAFETY LABELS
CLEARING JAMS
WARNING!
1. Read and understand operating manual
before using.
2. Operator and all the by-standers must wear
ANSI approved safety glasses, ear and head
protections.
3. Never use oxygen or other fl ammable gases.
Only choose clean dry regulated compressed
air below 100 PSI pressure.
4. Remove fi nger from trigger while not
operating.
5. Never trip over the hose. Make sure all
connections are tight.
6. Disconnect the tool from air supply before
clearing jams, serviceing, adjusting or during
non-operation.
7. Don’t point tool at people or animals while
operating.
Operating Pressure
70 - 100 psi
Driving Blade
1. Disconnect air supply.
2. Pull the release lever to
unlatch magazine cover
and slide it to the rear
3. Use the release lever to
remove the nose-cover
assmebly.
4. Inspect and clear
the driveblade path
of any material or
debris.
Drive
Blade
Path