Troubleshooting

TROUBLESHOOTING

DANGER: 

ALWAYS DISCONNECT AC POWER CORD PRIOR 
TO MAKING ANY DC WIRING CONNECTION
CHANGE OR WHEN CHECKING FUSES.

Problem

Possible Cause

Solution

Power indicator is 
not on.

No AC input.

Check AC input connection.  Make sure AC 
power is present.

Short circuit at DC 
output. 

Check and correct battery wiring connection 
(Refer to wiring connection charts).  Replace  
broken fuse if necessary.

Over-Voltage  
warning indicator is 
on (amber)

Battery voltage 
exceeds safe 
range.

Check and correct battery wiring connec-
tion. (Refer to wiring connection charts.)  
Make sure each output is connected to one 
12V battery.  Wait at least 30 seconds before 
plugging in AC power again.
If Over-Voltage LED continues to be on even 
with correct wiring connections, unplug the 
charger’s AC power input and stop using 
the charger to avoid possible damage to the 
battery and/or connected devices.

Overheat warning  
indicator LED is on 
(amber)

Ambient tempera-
ture exceeds safe 
range.

Remove objects obstructing airflow around 
the charger.  If the charger was operated un-
der direct sunlight, move it away from direct 
sunlight exposure.  Charger will wait for the 
temperature to come down, then automati-
cally start again.

Charge Status / 
Connection Check 
LED displays amber

The output cable is 
not connected to a 
12V battery.

Properly connect the DC output to a 12V 
battery.  Refer to wiring connection charts.

Fuse failure.

Check for blown fuses on the output cables.  
Replace damaged fuses.

Faulty terminal 
connections.

Clean battery terminal and tighten all wiring 
connections.

Reverse polarity on 
DC wiring connec-
tions.

Make sure connections have a matching 
polarity.  Check fuses on output cables and 
replace any damaged fuses.

Damaged battery.

Perform battery test.  Replace damaged 
batteries.

Содержание Turbo M212V2

Страница 1: ...V Turbo M212V2 2 12 Amps Turbo M220V2 2 20 Amps Turbo M320V2 3 20 Amps Turbo M230V2 2 30 Amps Turbo M330V2 3 30 Amps Turbo M430V2 4 30 Amps Turbo M240V2 2 40 Amps Turbo M340V2 3 40 Amps Turbo M440V2 4...

Страница 2: ...ion For this reason it is extremely important to follow the safety instructions each time you use the charger Do NOT use the charger with a 2 pin AC adapter or extension cord Do NOT cut or make any mo...

Страница 3: ...ts 4 Specifications 5 Feature Highlights 8 Installing the charger 10 Select battery type 11 Connect the DC cables 12 Operating the charger 17 LED indicator descriptions 17 Troubleshooting 18 Fuse repl...

Страница 4: ...water and soap nearby in case battery acid comes in contact with skin clothes or eyes 4 Wear complete eye protection and protective clothing Avoid touching your eyes while working near batteries 5 If...

Страница 5: ...acturer Do not overfill For batteries without cell caps follow the recharging instructions provided by battery manufacturers If necessary use only industrial grade UL approved extension cord that conn...

Страница 6: ...s 4 7 Amps 4 7 Amps 7 0 Amps 12V Output Prewired 2 2 3 2 Maximum Output 12 Amps 20 Amps 20 Amps 30 Amps Output Voltage Configuration 12 24V DC 12 24V DC 12 24 36V DC 12 24V DC Weight 6 5 lb 7 7 lb 8 2...

Страница 7: ...7 0 Amps 9 3 Amps 9 3 Amps 9 3 Amps 3 4 2 3 4 30 Amps 30 Amps 40 Amps 40 Amps 40 Amps 12 24 36V DC 12 24 36 48V DC 12 24V DC 12 24 36V DC 12 24 36 48V DC 13 5 lb 14 0 lb 13 5 lb 14 0 lb 14 5 lb 103 4...

Страница 8: ...ator 4 Overheat indicator 5 AGM charge mode 6 GEL Gel Cell charge mode 7 Flooded Lead Acid AGM charge mode LED indicators bottom Charge status DC connection check Feature highlights Adaptive Loading 3...

Страница 9: ...s Adaptive Loading allocates approximately 50 percent of it total output equally to each battery In Scenario 2 right side the first battery s is close to full charge and the second battery is nearly d...

Страница 10: ...e battery charges up to 100 When the battery is fully charged the charger then moves to the third stage At the third stage Float the charger voltage now drops to 13 4V flooded AGM mode At this point i...

Страница 11: ...and soldering 12 AWG for 12 Amp and 20 Amp models or 10 AWG for 30 Amp and 40 Amp wires Each splice should be covered by adhesive lined dual wall heat shrink tube to prevent corrosion at the joints Th...

Страница 12: ...Odyssey and Optima brands AGM To switch to a different charge mode 1 Make sure the charger s power cord is unplugged from the power outlet 2 Loosen the screws from the battery selector 3 Carefully pul...

Страница 13: ...rams and the black ones are negative Never connect a black wire negative to a terminal that is connected with a red wire positive ALL charger s output cables must be connected to the battery terminal...

Страница 14: ...atteries linked in series Output 1 Output 2 Connect both sets of DC outputs to the same battery s terminal If a 12V system is composed of two 6V batteries connect the output s postive terminal ring to...

Страница 15: ...put charger to two serial connected 12V batteries 24V system Connect one set of output to each 12V battery The jumper can be left connected between the two batter ies during charging Connect one set o...

Страница 16: ...ies Combining two chargers to a single bank Output 1 Output 1 Combine multiple Turbo MV2 chargers to form a more powerful charging system by connecting both chargers outputs to the same battery bank O...

Страница 17: ...harger to three 12V batteries DC wiring connections O u t p u t 3 Ou tp ut 2 O ut pu t 1 The batteries could be indepen dent serial connected or parallel connected O u tp u t 3 O u t p u t 4 O u tp u...

Страница 18: ...temperature 8 When a recharge cycle is completed the charger will go into monitor mode and continue to trickle charge the batteries at float voltage It is safe to leave the charger s power on and con...

Страница 19: ...harger s AC power input and stop using the charger to avoid possible damage to the battery and or connected devices Overheat warning indicator LED is on amber Ambient tempera ture exceeds safe range R...

Страница 20: ...gently press the rubber enclosure as illustrated in the drawing below When installed preoperly the round metal plate will be securely tight ened inside the fuse holder Do not apply excessive force as...

Страница 21: ...d Santa Clara CA 95054 Tel 888 581 8168 408 228 4868 Fax 408 228 4878 email support powermaniausa com www powermaniausa com CONTACT INFORMATION Powermania at its discretion provides 2 year limited war...

Страница 22: ...21 www powermaniausa com Memo...

Страница 23: ......

Страница 24: ...Powermania Inc 2932 Scott Blvd Santa Clara CA 95054 USA...

Страница 25: ...RWV2 1404 Rev A R...

Отзывы: