18
500Wi OM
Batteries give off explosive gases; keep spark, flames and cigarettes away. Provide
adequate ventilation when charging.
Batteries contain sulfuric acid (electrolyte). Contact with skin or eyes may cause severe
burns. Wear protective clothing and a face shield.
If electrolyte gets on your skin, flush with water.
If electrolyte gets in your eyes, flush with water for at least 15 minutes and call a
physician immediately.
Electrolyte is poisonous.
-If swallowed, drink large quantities of water or milk and follow with milk of
magnesia or vegetable oil and call a physician immediately.
KEEP OUT OF REACH OF CHILDREN.
The DC receptacle may be used while the AC power is in use.
An overloaded DC circuit will trip the DC circuit breaker. If this happens reset the circuit
breaker to resume operation.
4.8 Low oil alarm system
The low oil alarm system is designed to prevent engine damage caused by an insufficient amount of oil in the
crankcase. Before the oil level in the crankcase falls below a safe limit, the low oil alarm system will automatically
shut down the engine (the engine switch will remain in the
“ON” position).
If the low oil alarm system shuts down the engine, the low oil alarm indicator light (Red) will come on when you
pull the starter rope and the engine will not run. If this occurs add enough of the approved engine oil to raise the
level to the top line on the dipstick.
Battery Charge Circuit Breaker
Low Oil Light (Red)