Owner’s Manual
Instructions for Installation/Set-up, Operation, Servicing, & Storage
Portable, Outdoor Use-Only, Dual Fuel Generator
Can be used to power individual appliances plugged directly into the generator’s outlets, or as a back
-up
connection to a building’s power supply (via a professionally installed
UL-listed transfer switch).
WARNING
READ and UNDERSTAND this manual completely before using the generator!
Failure to properly set up, operate, and
maintain this generator could result in
serious injury or death
from
carbon monoxide poisoning, electric shock,
fire/explosion, or burns
. In particular, be aware of the following hazards:
CO Poisoning
Generators give off carbon monoxide, a poisonous gas that can kill you. You CANNOT smell it, see it, or taste it.
•
ONLY run generator OUTDOORS and AWAY from building air intakes. NEVER run generator inside any enclosed or semi-enclosed
spaces, including homes, basements, garages, sheds, boxes, RVs, boats or pick-up truck beds. These spaces can trap poisonous
gases, EVEN if you run a fan or open windows.
•
Carbon monoxide is given off whether you are using gasoline or propane to power the generator.
•
Install carbon monoxide alarms inside nearby structures/buildings (battery-operated, or plug-in with battery backup).
Electric shock / Electrocution
•
High voltage electricity from generator can kill. DO NOT operate in wet locations. Be sure generator is properly grounded. Use only
UL-listed, outdoor-rated grounded extension cords of proper size.
•
NEVER plug the generator directly into a wall outlet. ANY connection to a building’s electrical system
MUST ISOLATE THE
GENERATOR FROM UTILITY POWER via a UL-listed transfer switch installed by a licensed electrician. Otherwise, back feed from
the generator into the power grid could kill utility workers.
Fire / Explosion
•
DO NOT overload generator (per rated capacity), and OPERATE ONLY in an area with adequate cooling ventilation so engine does
not overheat. Exhaust can be extremely hot. Keep muffler at least 7 feet from all combustible objects.
•
All fuels are flammable. Never fuel a running or hot engine. Never pump fuel directly into generator at gas station
–
use approved
container to transfer fuel. Ensure there are no fuel leaks, and keep sources of sparks and flames away.
•
Propane hook-ups must be completed by a certified propane technician and comply with all federal and local requirements.
•
ALWAYS keep a fire extinguisher rated “ABC” nearby.
STOP!
CHOOSE THE RIGHT GENERATOR FOR YOUR NEEDS.
See the “Power Load Planning & Management” section of this manual to
determine your power load requirements and then compare to the generator’s rated capacity.
INSPECT COMPONENTS
: Closely inspect to make sure no components are missing or damaged. See
the “Unpacking & Delivery
Inspection” section for instructions on whom to contact to report missing or damaged parts.
ARRANGE FOR PROFESSIONAL INSTALLATION
of a transfer switch if you will be connecting the generator to your building’s
electrical system and for propane hook-ups.
See the “Installation/Initial Set
-
Up” section for more information about this requirement.
ADD ENGINE OIL:
Engine is shipped
without oil
. See engine section of this manual for instructions on capacity and viscosity
recommendations.
Any Questions, Comments, Problems, or Parts Orders
Call Powerhorse Product Support 1-866-443-2576
M750133B.4
ITEM NUMBER:
750133
SERIAL NUMBER:
_______________
Содержание 750133
Страница 2: ...Hazard Signal Word Definitions 2...
Страница 8: ...Safety Label Locations 8 17 14 1 2 5 3 4 6 7 8 9 10 11 12 16 13 15 18 19...
Страница 48: ...750133 Parts Explosion Rev B 4 48...
Страница 52: ...797283 Engine Parts Explosion Rev B 4 52...