background image

I

NSTRUCTIONS 

M

ANUAL 

D

IGIT 

3001 

 

 

 

R

ELEASE

.

 

N.2_M

   

13_10_08

 

P

OWERGEN 

S.

R

.

L

.

 

V

IA  

XXV

 

A

PRILE

,

 

5

 

L

OC

.

 

C

ORSALONE 

C

HIUSI DELLA  

V

ERNA 

(A

REZZO

)

 +39-(0)575-531015 - T39-(0)575-511891 E mail 

[email protected]

    

www.batterychargerpowergen.it

 P.Iva 01572290516

  

 

- 15 -

 

 

 

Once the charging cycle has started, it can be manually interrupted by pressing the left-

hand “

ON/OFF

” button. “

StoP

” 

 will be shown on the display. By pressing the 

left-hand "

ON/OFF

" button again, the charging cycle will be enabled. This will be started 

again automatically after 5 seconds. The cycle will resume from where it stopped. 
 
The display menu is also available during the cycle interruption. By pressing the middle 
"

A/V

" button, the User will be able to browse the display menu and to scroll and read the 

following charging parameters:  
 

-

 

charging current

 in real time: “

A. XXX

”; 

-

 

battery voltage

 in real time: “

U.XXX

”; 

-

 

voltage per cell

 in real time: “

E.XXX

”; 

-

  Total time of performed charge: “

t.XXX

”; 

-

 

charging time 

of performed

 timed cycle

: “

F.XXX

”; 

-

 

delivered capacity (ampere-hours integrated into the battery):

 “

AH.

” “

XXXX

”. The 

value is shown in two subsequent displays. Display “

XXXX

”  is shown automatically 

after about 1 second from display “

AH.

” 

 
Should mains voltage fail during the operation of the charging cycle, this will be interrupted 

and “

StoP

” 

 will be shown on the display. Once mains voltage is restored, the 

cycle will start again automatically after 5 seconds from where it stopped. 
 
In case of battery disconnection during the charging cycle, this will be interrupted and 

UMIn

”  

 will be shown on the display first and then “

bdIS

” 

. As soon as 

the battery is reconnected, the cycle will resume its operation from the start (

initial charge

), 

setting to zero the active time meters, if any. “

StoP

” 

 and then “

nor

” 

 

will be shown on the display.  
 
If the battery cable is disconnected when the cycle has finished or has not yet started, 

UMIn

” 

 will be shown on the display. 

 

8.2.2. 

LED bar 

During the charging cycle, the card will not only control the display of charging parameters, 
but also the switching on/off of the LED's on the front panel (see General Description) 
based on the following sequence: 
in case of mains and battery present, before the cycle starts automatically, the second 
LED "

battery connected

" will be steadily lit. Once the charging cycle has started (

initial 

charge

) the same LED will start blinking. Once the battery threshold voltage is reached, 

the third LED "

timed cycle

" will be steadily lit and after three minutes the 

timed 

charging 

cycle

 will start and the LED will start blinking. After the time set in the 

timed cycle

 has 

elapsed, the charging cycle will be completed and the fourth LED "

charge completed

" will 

be steadily lit (the second one will remain steadily lit and the third one will be off). 

 

Содержание Digit 3001

Страница 1: ...ELLA VERNA AREZZO 39 0 575 531015 Telefax 39 0 575 511891 E mail borri elledi it www batterychargerpowergen it P Iva 01572290516 1 Digit 3001 Single Three phase Instructions manual UK Warranty UK Read...

Страница 2: ...6 4 MAINTENANCE 7 5 OPERATION 8 6 WARRANTY 9 6 1Problem Solutions and checks 10 7 REQUEST OF SPARE PARTS AND OR SERVICE REQUEST 11 8 DIGIT 3001 11 8 1 Operation mode PROGRAMMING 12 8 2 Operation mode...

Страница 3: ...23 EEC Electric material used within specific voltage limits later modified by directive 93 68 EEC 89 336 EEC Electromagnetic compatibility later modified by directive 92 31 EEC The following equipmen...

Страница 4: ...rson who takes following obligations according to the agreements made by owner and USER The USER will be responsible for the installation site of the charger He shall check whether very sensitive appl...

Страница 5: ...not lay any materials which may obstruct the natural cooling air flow q The rectifier shall be laid on the floor in vertical position For special requirements it may also be placed on special raised...

Страница 6: ...recommend to check the actual value of the mains voltage if found high or low compared with the rated values may cause problems due to a higher or lower delivery of current during the charge q As a r...

Страница 7: ...necting the rectifier from mains and from the battery q For a correct operation we recommend to check the mechanical tightening of electric connections and the good status of wires and connections and...

Страница 8: ...Maximun time Lights if the battery charter has not completed its cycle within 12 hours The electronic card is provided with a safety timer interrupting the cycle in order not to damage the battery The...

Страница 9: ...rger warranty is 12 twelve months from its start up q The warranty covers all proven defects in components assembly and construction q Any incorrect installation or use of the charger NULLIFIES the wa...

Страница 10: ...put Check the efficiency of the remote control switch coil The battery charger is not charging sufficiently Check the supply voltage In case it is low modify the tap on the transformer 5 Make sure the...

Страница 11: ...tween operation modes and between execution times can be done by directly selecting the correct position of the dip switch as shown on the card silk screen print without disconnecting the supply durin...

Страница 12: ...wing parameters can be set via this card amount of stages rated battery voltage battery threshold voltage charging time in timed charging cycle maximum safety cycle time battery minimum voltage batter...

Страница 13: ...programmed in point 4 With charging mode 01 if the battery voltage reaches the threshold voltage in more than 2 hours the timed charging cycle shall be entirely performed as programmed Otherwise the t...

Страница 14: ...essed in minutes delivered capacity ampere hours integrated into the battery AH XXXX expressed in ampere hours The value is shown in two subsequent displays Display XXXX is shown automatically after a...

Страница 15: ...StoP will be shown on the display Once mains voltage is restored the cycle will start again automatically after 5 seconds from where it stopped In case of battery disconnection during the charging cy...

Страница 16: ...cles C XXX At the end of the equalized charging cycle End will be shown on the display 8 3 2 LED bar During normal charging cycles before completing the charge the User may retrieve the equalization f...

Страница 17: ...hours integrated into the battery AH and after 1 second XXXX expressed in ampere hours After 10 seconds of buttons inactivity the display will show Sto again and then End 8 5 Alarms and Safeties DIGIT...

Страница 18: ...Monitor and supervision of the correct microprocessor operation via an external supervising circuit The supervising circuit is supplied with a watchdog timer to which pulses are periodically sent by t...

Страница 19: ...al Charge at decreasing current with intervention of the final charge at 2 40 V cell Final charge with timed control 9h 11h Fixed charging time equalization charge excluded Equalization charge week en...

Страница 20: ...erna AREZZO DECLARES that the battery charger of Powergenprocessor type Digit 3001______ Serial N __________ manufacturing year 200__ Complies with the following standards q DIN 41772 3 4 Charging met...

Страница 21: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 22: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____...

Страница 23: ...di it www batterychargerpowergen it P Iva 01572290516 23 ORDER FOR SPARE PARTS BATTERY CHARGER Powergenprocessor Customer s stamp and signature Fill in and send to Powergen S r l Via XXV Aprile 5 Loc...

Страница 24: ...575 511891 E mail borri elledi it www batterychargerpowergen it P Iva 01572290516 24 Thank you very much for choosing our product Congratulations on your decision This equipment is the result of the...

Страница 25: ...ww batterychargerpowergen it P Iva 01572290516 25 WARRANTY CERTIFICATE Powergenprocessor ________________ Customer s stamp and signature Fill in and send to Powergen S r l Via XXV Aprile 5 Loc Corsalo...

Страница 26: ...ate otherwise the certificate will be void Warranty is exclusively meant as a free of charge repair or replacement of components which have been acknowledged to be faulty in their manufacture or mater...

Отзывы: