Oilless Tankmount Duplex

Maintenance Schedule

Item

action 
needed

operating Hours

Remarks

Daily

500

1500

2500

5000

10,000 15,000 20,000

Tank

Drain moisture

l

Drain tank daily

Inlet air filter Replace

l

s

Every 2500 hours 

or less

Blower fan

Clean

l

l

l

l

Fan duct

Clean

l

l

l

l

Compressor 

fins

Clean

l

Every 2500 hours 

or less

Compression 

rings

Replace

l

s

l

s

Every 2500 hours 

or less

Wrist pin 

bearing

Regrease

s

s

s

s

Replace high 

pressure wrist pin

Piston set

Inspect

l

l

V-belt

Inspect, 

Replace

l

s

s

s

s

See Note 3

Pressure 

switch

Confirm 

operation

l

l

Magnetic 

starter

Inspect

l

l

Replace if contact  

points deteriorated

Safety valve

Confirm 

operation

l

Every 2500 hours  

or 6 months

Pressure 

gauge

Inspect

l

Every 2500 hours 

or less

  l

  Inspect

 

s

  Replace

noteS:

1. Inspect and perform maintenance periodically according to maintenance schedule.
2. The maintenance schedule relates to the normal operating conditions. If the circumstances and load condition  

are adverse, shorten the cycle time and do maintenance accordingly.

3. The tension of the V-belt should be adjusted during initial start up and inspected every 1,500 hours afterwards.  

Proper belt tension for 1 to 3 HP units is 2-3 lbs. / 0.5 inch deflection; for 5 to 15 HP units, 4-6 lbs. / 0.5 inch deflection.

Содержание OTD010

Страница 1: ...tors Three year warranty on compressor pump Optional Isolation pads Optional R134 dryer ASME tank UL listed controls with optional panel NORGREN N OUTLET INLET IN OUT 1 2 X 1 4 2 X 1 1 2 RESET RESET 0 0 0 0 0 0 0 PUMP NO 2 ALT PUMP NO 1 0 0 0 0 0 80 PRESSURE GAGE 40 20 60 PSI 100 0 ON min TEST OFF 45 sec 0 5 2 4 10 50 5 20 8 6 30 40 PSI 160 200 60 0 20 100 180 PRESSURE GAGE 80 140 120 40 The perfo...

Страница 2: ...y Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a potentially minor or moderate injury Notice indicates important information that if not followed may cause damage to equipment NOTE Information that requires special attention California proposition 65 This product or its power cord may contain chemicals known to t...

Страница 3: ...1 4 26 3 4 20 45 3 4 40 18 14 5 8 80 5 8 500 480 OTD 030 3XX 65 3 8 26 3 4 20 45 3 4 40 18 14 5 8 80 5 8 500 480 OTD 130 3XX 65 3 8 26 3 4 20 45 3 4 40 18 14 5 8 80 5 8 500 480 OTD 030 4XX 70 3 4 27 3 4 24 50 1 4 42 18 16 7 8 82 3 4 780 760 OTD 130 4XX 70 3 4 27 3 4 24 50 1 4 42 18 16 7 8 82 3 4 780 760 OTD 050 4XX 70 3 4 29 1 4 24 58 1 4 42 18 16 7 8 930 910 OTD 151 4XX 70 3 4 29 1 4 24 58 1 4 42...

Страница 4: ...is ready for full operation No break in is required Operation Factory calibrated snap acting DPST pressure electric switches provide automatic cut in and cut out Overpressure protection is provided by an ASME safety relief valve Receiver tanks have a condensate drain valve with an extension for easy access All mounting bases are slotted for V belt tension adjustment to aid in maintaining proper co...

Страница 5: ...re switch Confirm operation l l Magnetic starter Inspect l l Replace if contact points deteriorated Safety valve Confirm operation l Every 2500 hours or 6 months Pressure gauge Inspect l Every 2500 hours or less l Inspect s Replace NOTES 1 Inspect and perform maintenance periodically according to maintenance schedule 2 The maintenance schedule relates to the normal operating conditions If the circ...

Страница 6: ...6 Oilless Tankmount Duplex Figure 3 Single Phase Wiring Diagram ...

Страница 7: ...7 Oilless Tankmount Duplex Figure 4 Three Phase Wiring Diagram ...

Страница 8: ...r HP 1 1 1 2 2 0 1 91237640 2 3 4 0 1 91237640 5 High pressure 2 0 1 91930680 5 Low pressure 2 0 1 91236681 7 1 2 10 High pressure 2 0 1 91930680 7 1 2 10 Low pressure 4 0 1 91236671 15 High pressure 2 0 1 91930680 15 Low pressure 4 0 1 91236681 D Intake Filter Element Motor HP 1 1 1 2 2 0 2 ST073923AV 2 3 2 0 2 ST073905AV 5 2 0 3 ST073905AV 7 1 2 10 2 0 3 ST073907AV 15 2 0 3 ST073907AV E Belt Mot...

Страница 9: ...827 kPa cut out 1 0 9 CW207558AV Lag Switch Set at approximately 80 psig 560 kPa cut in and 110 psig 758kPa cut out 1 0 9 CW207559AV K Tank Motor HP Tank Size 1 Through 1 1 2 30 gallon 1 134 0 AR022600ST 2 3 80 gallon 1 243 0 AR022900ST 3 120 gallon 1 415 0 AR023600ST 5 120 gallon 1 415 0 AR022800ST 5 200 gallon 1 677 0 JQ000200AJ 7 1 2 Through 15 240 gallon 1 810 0 JQ000100AJ L COOLING SHROUD Mot...

Страница 10: ...Notes 10 Oilless Tankmount Duplex ...

Страница 11: ...Notes 11 Oilless Tankmount Duplex ...

Страница 12: ...tions iii that have been materially modified without the prior written approval of Powerex or iv that experience failures resulting from operation either intentional or otherwise in excess of rated capacities or in an otherwise improper manner f The warranty provided herein shall not apply to i any defects arising from corrosion abrasion use of insoluble lubricants or negligent attendance to or fa...

Отзывы: