background image

2

Oilless Tankmount Duplex

Installation

MounteD anD ConneCteD optIonS
Magnetic Motor Starter

An optional magnetic motor starter which has been selected 
and wired for the intended input voltage is available for all 
units. All starters are furnished with properly sized overload 
relay.

Refrigerated air Dryer

A factory mounted refrigerated air dryer with automatic 
condensate drain trap assembly and bypass valve is available 
as an option on all 1/2 through 3 HP Powerex Duplex Air 
Compressors. The air dryer is piped to the compressor at the 
factory; power wiring to the dryer is done in the field using 
the integral cord and plug which fits into a standard 120 volt 
receptacle.

automatic tank Drain

Powerex air compressors are ordered with either a manual 
or electric type automatic tank drain. This unit is furnished 
with a manual drain as standard. An electric drain must be 
mounted to the compressor in the field.

Vibration Dampening pads

Waffle type design vibration pads are provided as optional 
equipment.

Safety Guidelines

This manual contains information that is very important 
to know and understand. This information is provided for 
SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help 
recognize this information, observe the following symbols.

 

Danger indicates an imminently  

  hazardous situation which, if 

not avoided, WILL result in death or serious injury.
 

Warning indicates a potentially  

  hazardous situation which, if 

not avoided, COULD result in death or serious injury.
 

Caution indicates a potentially 

  minor or moderate injury.

 

Notice indicates important  

  information, that if not 

followed, may cause damage to equipment.

note:

 Information that requires special attention.

CalIFoRnIa pRopoSItIon 65

 

This product or its power cord  

  may contain chemicals known 

to the State of California to cause cancer and birth defects or 
other reproductive harm. Wash hands after handling.

performance Specifications

Model

Hp

phase

SCFM @ 100 

psig

RpM

Voltage

Gallon 

tank

Dimensions 

l x W x H

Ship Weight 

(lbs.)

OTD110

1 (2)

1

7.2

625

115

 

/

 

208

 

/

 

230

30

42 x 21 x 35

272

80

64 x 22 x 39

432

OTD010

1 (2)

3

7.2

625

208

 

/

 

230

 

/

 

460

30

42 x 21 x 35

270

80

64 x 22 x 39

435

OTD115

1-1/2 (2)

1

10.6

885

115

 

/

 

208

 

/

 

230

80

65 x 23 x 41

439

OTD015

1-1/2 (2)

3

10.6

885

208

 

/

 

230

 

/

 

460

80

65 x 23 x 41

435

OTD120

2 (2)

1

13.2

845

115

 

/

 

208

 

/

 

230

80

65 x 23 x 41

504

OTD020

2 (2)

3

13.2

845

208

 

/

 

230

 

/

 

460

80

65 x 23 x 41

500

OTD130

3 (2)

1

20.2

1115

208

 

/

 

230

80

65 x 23 x 41

658

120

71 x 26 x 44

788

OTD030

3 (2)

3

20.2

1115

208

 

/

 

230

 

/

 

460

80

65 x 23 x 41

650

120

71 x 26 x 44

780

OTD151

5 (2)

1

35.8

800

208

 

/

 

230

120

79 x 26 x 49

941

200

82 x 30 x 56

1167

OTD050

5 (2)

3

35.8

800

208

 

/

 

230

 

/

 

460

120

79 x 26 x 49

930

200

82 x 30 x 56

1155

OTD075

7.5 (2)

3

52.2

855

208

 

/

 

230

 

/

 

460

240

86 x 51 x 69

1430

OTD100

10 (2)

3

70

1090

208

 

/

 

230

 

/

 

460

240

86 x 51 x 69

1510

OTD150

15 (2)

3

108.4

1140

208

 

/

 

230

 

/

 

460

240

86 x 51 x 69

1620

note: 

See Electrical Diagram shipped with the unit for Motor Full Load Amp Ratings

Содержание OTD010

Страница 1: ...tors Three year warranty on compressor pump Optional Isolation pads Optional R134 dryer ASME tank UL listed controls with optional panel NORGREN N OUTLET INLET IN OUT 1 2 X 1 4 2 X 1 1 2 RESET RESET 0 0 0 0 0 0 0 PUMP NO 2 ALT PUMP NO 1 0 0 0 0 0 80 PRESSURE GAGE 40 20 60 PSI 100 0 ON min TEST OFF 45 sec 0 5 2 4 10 50 5 20 8 6 30 40 PSI 160 200 60 0 20 100 180 PRESSURE GAGE 80 140 120 40 The perfo...

Страница 2: ...y Warning indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Caution indicates a potentially minor or moderate injury Notice indicates important information that if not followed may cause damage to equipment NOTE Information that requires special attention California proposition 65 This product or its power cord may contain chemicals known to t...

Страница 3: ...1 4 26 3 4 20 45 3 4 40 18 14 5 8 80 5 8 500 480 OTD 030 3XX 65 3 8 26 3 4 20 45 3 4 40 18 14 5 8 80 5 8 500 480 OTD 130 3XX 65 3 8 26 3 4 20 45 3 4 40 18 14 5 8 80 5 8 500 480 OTD 030 4XX 70 3 4 27 3 4 24 50 1 4 42 18 16 7 8 82 3 4 780 760 OTD 130 4XX 70 3 4 27 3 4 24 50 1 4 42 18 16 7 8 82 3 4 780 760 OTD 050 4XX 70 3 4 29 1 4 24 58 1 4 42 18 16 7 8 930 910 OTD 151 4XX 70 3 4 29 1 4 24 58 1 4 42...

Страница 4: ...is ready for full operation No break in is required Operation Factory calibrated snap acting DPST pressure electric switches provide automatic cut in and cut out Overpressure protection is provided by an ASME safety relief valve Receiver tanks have a condensate drain valve with an extension for easy access All mounting bases are slotted for V belt tension adjustment to aid in maintaining proper co...

Страница 5: ...re switch Confirm operation l l Magnetic starter Inspect l l Replace if contact points deteriorated Safety valve Confirm operation l Every 2500 hours or 6 months Pressure gauge Inspect l Every 2500 hours or less l Inspect s Replace NOTES 1 Inspect and perform maintenance periodically according to maintenance schedule 2 The maintenance schedule relates to the normal operating conditions If the circ...

Страница 6: ...6 Oilless Tankmount Duplex Figure 3 Single Phase Wiring Diagram ...

Страница 7: ...7 Oilless Tankmount Duplex Figure 4 Three Phase Wiring Diagram ...

Страница 8: ...r HP 1 1 1 2 2 0 1 91237640 2 3 4 0 1 91237640 5 High pressure 2 0 1 91930680 5 Low pressure 2 0 1 91236681 7 1 2 10 High pressure 2 0 1 91930680 7 1 2 10 Low pressure 4 0 1 91236671 15 High pressure 2 0 1 91930680 15 Low pressure 4 0 1 91236681 D Intake Filter Element Motor HP 1 1 1 2 2 0 2 ST073923AV 2 3 2 0 2 ST073905AV 5 2 0 3 ST073905AV 7 1 2 10 2 0 3 ST073907AV 15 2 0 3 ST073907AV E Belt Mot...

Страница 9: ...827 kPa cut out 1 0 9 CW207558AV Lag Switch Set at approximately 80 psig 560 kPa cut in and 110 psig 758kPa cut out 1 0 9 CW207559AV K Tank Motor HP Tank Size 1 Through 1 1 2 30 gallon 1 134 0 AR022600ST 2 3 80 gallon 1 243 0 AR022900ST 3 120 gallon 1 415 0 AR023600ST 5 120 gallon 1 415 0 AR022800ST 5 200 gallon 1 677 0 JQ000200AJ 7 1 2 Through 15 240 gallon 1 810 0 JQ000100AJ L COOLING SHROUD Mot...

Страница 10: ...Notes 10 Oilless Tankmount Duplex ...

Страница 11: ...Notes 11 Oilless Tankmount Duplex ...

Страница 12: ...tions iii that have been materially modified without the prior written approval of Powerex or iv that experience failures resulting from operation either intentional or otherwise in excess of rated capacities or in an otherwise improper manner f The warranty provided herein shall not apply to i any defects arising from corrosion abrasion use of insoluble lubricants or negligent attendance to or fa...

Отзывы: