IMPORTANT SAFETY INSTRUCTION

1.

 

WARNING: SAVE THESE INSTRUCTIONS!!

 

 

WARNING: Manual contains important instructions of UPS and batteries during installation 

and maintenance. Follow this instruction at all time 

 

WARNING:

 It is recommended to install UPS in an ANSI/NFPA75 room in which temperature 

and humidity are controlled and free from electrically conductive particles. 

DO NOT 

expose 

UPS to direct sunlight or high heat source; 

DO NOT

 block off ventilation opening around the 

housing.

 

 

CAUTION:

  Before  conducting  maintenance,  repair,  or  shipment,  please  turn  off  everything 

completely and disconnect them. 

 

CAUTION: 

The  UPS  is 

NOT

  applicable  for  any  inductive  loads  such  as  motors  or  domestic 

appliances like hairdryers, speakers, and fluorescent lamps.

 

 

CAUTION:

  All  interconnection  and  power  cable  should  be  connected 

ONLY  AFTER 

the  UPS 

shut down and disconnected from main. 

 

CAUTION:

 Only use No.26 AWG or larger certified cables to connect UPS and device.

 

 

CAUTION:

 

DO NOT

 unplug UPS from main power during operation or protective ground will 

fail. 

DO NOT

 disconnect battery under load or shut down may occur.

 

 

CAUTION: 

Ensure  the  total  leakage  current  of  UPS  and  the  connected  equipment  under 

3.5mA. 

 

CAUTION: 

Ensure  UPS  connects  to  grounded  main  power  with  a  fuse  or  circuit  breaker 

protection.

 

 

CAUTION:

 Dangerous amount of voltage might still exist even the UPS disconnects from the 

main power since residual voltage exists due to battery supply.

 

 

CAUTION:

 Beware of all the details on the cautionary sticker located on UPS.

 

 

CAUTION  (No  user-serviceable  parts):

  Do  not  attempt  to  remove  the  unit’s  cover,  no 

user-serviceable parts inside. Please refer all service to qualified service technicians.

 

 

CAUTION:

 

DO NOT

 dispose UPS and its batteries to fire, the battery may explode.

 

 

CAUTION:

 

DO NOT

 attempt to open or mutilate the battery.

 

 

User’s operations

: Users only permits to:

 

• Turning the UPS unit on and off. 

• Operating the user interface. 

• Connecting data interface cables. 

• Changing the batteries.

 

 

CAUTION:

 Battery can cause shock and short circuit current. When servicing batteries:

 

A.

 

Remove watches, rings, or other metal objects.

 

B.

 

Use tools with insulated handles.

 

C.

 

Wear rubber gloves and boots.

 

D.

 

Please 

DO NOT

 place any tools or metal parts on top of batteries. 

 

E.

 

Disconnect charging source before connecting/disconnecting battery terminals.

 

F.

 

Servicing  of  batteries  should  be  performed  or  supervised  by  personnel  with  necessary 

precautions and knowledge. Keep unauthorized personnel away from batteries.

 

 

DANGER:

  Hazardous  electric  component  inside  this  unit  (example:  Heat-sinks)  remain 

energized from the battery supply even when the main power is disconnected.

 

 

DANGER:

  Battery  circuit  is  not  isolated  from  the  AC  input.  Hazardous  voltage  may  exist  at 

battery terminals and ground—test for safety before any direct contact.

 

 

CAUTION: 

Remove the battery’s pole during service inside the battery cabinet or UPS.

 

 

CAUTION:

 

ONLY

 replace batteries with the same type and quantity.

 

WARNING (Fuses)

: Ensure fuse replacement with the same type and rating 

ONLY

.

 

Содержание 1500AP

Страница 1: ...U P S Line Interactive 1025VA 3000VA USER MANUAL...

Страница 2: ...tions If by turning on and off you conclude that the equipment s harmful interference influences your radio or television reception use one of the following preventive measures Place the receiving ant...

Страница 3: ...4 3 1 Rear panel view 4 3 2 Connection to Main and Load 4 4 Operation 5 4 1 General Description 5 4 2 System Configuration 5 4 3 UPS Control 5 4 4 UPS Configuration 6 5 UPS Monitoring Connection 7 6 M...

Страница 4: ...e main power since residual voltage exists due to battery supply CAUTION Beware of all the details on the cautionary sticker located on UPS CAUTION No user serviceable parts Do not attempt to remove t...

Страница 5: ...zardous situations to personnel and equipment Ensure the main power voltage matches with UPS 110V 220V For electrical installation closely observe the nominal current rating of the source Check the eq...

Страница 6: ...revent battery discharge Diagnostic Test While the advanced battery management system monitors the conditions of the batteries it sends early warnings if a battery replacement is needed Diagnostic tes...

Страница 7: ...during Line Mode Silence Press once to enable disable alarm buzzer during Battery Mode Green mode The Green mode feature will enable UPS no Load or light load shutdown to maintain power consumption an...

Страница 8: ...Storage Please read the following instructions if the UPS is not installed immediately Store the equipment as is in its original packing and shipping carton Do not store in temperatures outside the ra...

Страница 9: ...A Troubleshooting Troubleshooting procedures give simple instructions in determining UPS malfunctions Start the troubleshooting procedure if you witness any alarm indication Alarm The UPS has an audi...

Страница 10: ...The main voltage is out of the UPS input range UPS function normally check your main power voltage Overload Fault indicator lit or constant buzzer beeping UPS load exceed the capacity UPS overloading...

Страница 11: ...CD Control Panel IMD model Communication Port USB B type Physical Dimensions WxDxH mm 130 x 382 x 200 130 x 440 x 200 Weight kgs 13 5 13 5 16 16 6 22 Shipping Dimensions mm 253 x 488 x 321 253 x 556 x...

Отзывы: