Capacity

You must make sure your generator can supply enough
rated (running) and surge (starting) watts for the items you
will power at the same time. Follow these simple steps:
1.

Select the items you will power at the same time.

2.

Total the rated (running) watts of these items.This is
the amount of power your generator must produce to
keep your items running. See Figure 7.

3.

Estimate how many surge (starting) watts you will
need. Surge wattage is the short burst of power
needed to start electric motor-driven tools or
appliances such as a circular saw or refrigerator.
Because not all motors start at the same time, total
surge watts can be estimated by adding only the
item(s) with the highest additional surge watts to the
total rated watts from step 2.

Example:

Total Rated (Running) Watts

= 3075

Highest Additional  Surge Watts

=  1800

Total Generator Output Required = 4875

Power Management

To prolong the life of your generator and attached devices,
it is important to take care when adding electrical loads to
your generator.There should be nothing connected to the
generator outlets before starting it's engine.The correct
and safe way to manage generator power is to sequentially
add loads as follows:
1.

With nothing connected to the generator, start the
engine as described in this manual.

2.

Plug in and turn on the first load, preferably the largest
load you have.

3.

Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly.

4.

Plug in and turn on the next load.

5.

Again, permit the generator to stabilize.

6.

Repeat steps 4 and 5 for each additional load.

NEVER add more loads than the generator capacity.Take
special care to consider surge loads in generator capacity,
as described above.

*Wattages listed are approximate only. Check tool or
appliance for actual wattage.

Tool or Appliance

Rated (Running)

Watts

Additional Surge

(Starting) Watts

Window Air
Conditioner

1200

1800

Refrigerator

800

1600

Deep Freezer

500

500

Television

500

-

Light (75 Watts)

75

-

3075 Total

Running Watts

1800 Highest

Surge Watts

Tool or Appliance 

Rated* 

(Running) 

Watts 

Additional 

Surge 

(Starting) 

Watts 

Essentials 

 

 

Light Bulb - 75 watt 

75 

Deep Freezer 

500 

500 

Sump Pump 

800 

1200 

Refrigerator/Freezer - 18 Cu. Ft. 

800 

1600 

Water Well Pump - 1/3 HP 

1000 

2000 

Heating/Cooling 

 

 

Window AC - 10,000 BTU 

1200 

1800 

Window Fan 

300 

600 

Furnace Fan Blower - 1/2 HP 

800 

1300 

Kitchen 

 

 

Microwave Oven - 1000 Watt 

1000 

Coffee Maker 

1500 

Electric Stove - Single Element 

1500 

Hot Plate 

2500 

Family Room 

 

 

DVD/CD Player 

100 

VCR 

100 

Stereo Receiver 

450 

Color Television - 27” 

500 

Personal Computer w/17” monitor 

800 

Other 

 

 

Security System 

180 

AM/FM Clock Radio 

300 

Garage Door Opener - 1/2 HP 

480 

520 

Electric Water Heater - 40 Gallon 

4000 

DIY/Job Site 

 

 

Quartz Halogen Work Light 

1000 

Airless Sprayer - 1/3 HP 

600 

1200 

Reciprocating Saw 

960 

960 

Electric Drill - 1/2 HP 

1000 

1000 

Circular Saw - 7 1/4” 

1500 

1500 

Miter Saw - 10” 

1800 

1800 

Table Planer - 6” 

1800 

1800 

Table Saw/Radial Arm Saw - 10” 

2000 

2000 

Air Compressor - 1-1/2 HP 

2500 

2500 

Figure 7 - Wattage Reference Chart

www.mymowerparts.com

Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983

Содержание 30222

Страница 1: ...www briggsandstratton com PowerBOSS is a trademark of Briggs Stratton Power Products PowerBOSS es una marca registrada de Briggs Stratton Power Products Model Modelo 030222 5000W Before using this product read this manual and follow all Safety Rules and Operating Instructions CAUTION Antes de utilizar el producto lea este manual y siga todas las Reglas de Seguridad e Instrucciones de Uso PRECAUCIÓ...

Страница 2: ...lert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death The safety alert symbol is used with a signal word DANGER CAUTION WARNING a pictorial and or a safety message to alert you to hazards DANGER indicates a hazard which if not avoided will result in death or serious injury WARNING indicates a haza...

Страница 3: ...ENT Ensure spark plug muffler fuel cap and air cleaner are in place DO NOT crank engine with spark plug removed If fuel spills wait until it evaporates before starting engine WHEN OPERATING EQUIPMENT Do not tip engine or equipment at angle which causes fuel to spill This generator is not for use in mobile equipment or marine applications WHEN TRANSPORTING OR REPAIRING EQUIPMENT Transport repair wi...

Страница 4: ...mokes or emits flames unit vibrates excessively Improper treatment of generator can damage it and shorten its life CAUTION WHEN ADJUSTING OR MAKING REPAIRS TOYOUR GENERATOR Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester DO NOT check for spark with spark plug removed Unintentional ...

Страница 5: ...engine by filtering dust and debris out of intake air Choke Lever Used when starting a cold engine Circuit Breakers AC Each receptacle is provided with a push to reset circuit breaker to protect the generator against electrical overload Fuel Tank Capacity of five 5 U S gallons Grounding Fastener If required please consult a qualified electrician electrical inspector or local agency having jurisdic...

Страница 6: ...Engine oil Owner s manual Engine manual Wheel kit If any parts are missing or damaged call the generator helpline at 1 800 743 4115 INSTALL WHEEL KIT NOTE While the wheel kit is designed to greatly improve the portability of your generator it is not intended for over the road use You will need two 1 2 or 13mm open end wrenches or a socket wrench with 1 2 or 13mm sockets and a 15 16 wrench to insta...

Страница 7: ...use fuel which contains Methanol DO NOT mix oil with fuel 2 Clean area around fuel fill cap remove cap 3 Slowly add regular unleaded fuel to fuel tank Be careful not to overfill Allow about 1 5 of tank space for fuel expansion Figure 2 4 Install fuel cap and wipe up any spilled fuel CAUTION Refer to engine manual for oil fill information Damage to equipment resulting from failure to follow this in...

Страница 8: ... enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes or other openings that can allow exhaust gas to collect in a confined area Figure 3 Prevailing winds and air currents should be taken into consideration when positioning generator Figure 3 Generator Clearance Exhaust Port Typical Generator Shown When using gener...

Страница 9: ...in the engine owner s manual 4 Move fuel valve to Off position Fuel Valve is shown in the On position Figure 4 Fuel Valve See Don t Overload Generator Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect from generator before stopping generator Exceeding generators wa...

Страница 10: ...ch of these outlets is protected against overload by a push to reset circuit breaker Figure 6 Use each outlet to operate 120 Volt 60 Hz single phase loads requiring 1 800 1 8 kW watts at 15 Amps of current NEVER attempt to power a device requiring more amperage than generator or receptacle can supply DO NOT overload the generator See Don t Overload Generator Receptacles may be marked with rating v...

Страница 11: ...y and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add more loads than the generator capacity Take special care to consider surge loads in generator capacity as described above Wattages listed are approximate only Check tool or appliance for actual wattage Tool or Appliance Rate...

Страница 12: ...ine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voids and cracks of the rotor and stator winding insulation Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings Generator Cleaning Use a damp cloth to wipe exterior surfaces clean Use a so...

Страница 13: ...carburetor parts add fuel stabilizer into fuel tank and fill with fresh fuel Run the unit for several minutes to circulate the additive through the carburetor The unit and fuel can then be stored for up to 24 months Fuel stabilizer can be purchased locally DO NOT store fuel from one season to another unless it has been treated as described above Replace fuel container if it starts to rust Rust and...

Страница 14: ...onnected 1 Short circuit in a connected load 2 Generator is overloaded 3 Shorted generator circuit 1 Disconnect shorted electrical load 2 See Don t Overload Generator 3 Contact Authorized service facility Generator will not start or starts and runs rough Low oil level Fill crankcase to proper level or place generator on level surface Generator shuts down during operation 1 Out of gasoline 2 Low oi...

Страница 15: ...purposes are not warranted NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD ABOUT YOUR WARRANTY We welcome warranty repair and apologize to you f...

Страница 16: ... acerca de la garantía consulte con el manual del propietario del motor REGLAS DE SEGURIDAD Éste es el símbolo de alerta de seguridad Sirve para advertir al usuario de un posible riesgo para su integridad física Siga todos los mensajes de seguridad que figuren después de este símbolo para evitar lesiones o incluso la muerte El símbolo de alerta de seguridad es usado con una palabra PELIGRO ADVERTE...

Страница 17: ... el tapón del depósito de combustible y el filtro de aire están instalados NO arranque el motor sin la bujía instalada Si se ha derramado combustible espere a que se evapore antes de arrancar el motor CUANDO OPERE EL EQUIPO NO incline el motor o el equipo de tal manera que la combustible se pueda derramar Este generador no es apto para el uso en equipos móviles ni en aplicaciones marinas CUANDO TR...

Страница 18: ...a salida eléctrica El equipo produce chispas humo o emite llamas La unidad vibra de una manera excesiva El tratamiento inadecuado del generador puede dañarlo y acortar su vida productiva PRECAUCIÓN CUANDO AJUSTE O HAGA REPARACIONES A SU GENERADOR Siempre desconecte el alambre de la bujía y colóquelo donde no pueda entrar en contacto con la bujía CUANDO PRUEBE LA BUJÍA DEL MOTOR Utilice un comproba...

Страница 19: ...que tiene una capacidad de 5 galones americanos de gasolina sin contenido de plomo Tomacorriente Dobles de 120 Voltios AC 15 Amp Pueden ser utilizados para suministrar alimentación eléctrica para el funcionamiento de cargas del motor herramientas aparatos especiales e iluminación eléctrica de 120 Voltios AC a 15 Amperios monofásica de 60 Hz Tomacorriente Dobles de 120 Voltios AC 20 Amp Pueden ser ...

Страница 20: ...ad Principal Aceite del Motor Manual del Propietario Manual del Motor Juego de Ruedas Si cualquier parte falta o está dañada llame a la Línea de Ayuda del Generador al 1 800 743 4115 INSTALE EL JUEGO DE RUEDAS El juego de ruedas está diseñado para mejorar el transporte del generador NOTA Este Juego de Ruedas no ha sido diseñado para ser usado en la carretera Necesitará dos 1 2 o 13mm llaves ingles...

Страница 21: ... metanol ni mezcle aceite con combustible 2 Limpie el área alrededor de la tapa de llenado del combustible retire la tapa 3 Agregue lentamente combustible regular SIN PLOMO al tanque de combustible Use un embudo para evitar que se derrame Llene el tanque lentamente hasta aproximadamente 1 5 por debajo de la parte la cima del cuello del tubo de llenado Figura 9 4 Instale la tapa del tanque de combu...

Страница 22: ...s de escape no puedan entrar por ventanas puertas tomas de aire de ventilación u otras aberturas en un espacio cerrado en el que puedan acumularse Figura 10 Tenga en cuenta los vientos y las corriente de aire preponderantes cuando elija la ubicación del generador Figura 10 Espacio Libre Alrededor del Generador Salida del Escape Típica Generador Mostrada Cuando use un generador como poder de energí...

Страница 23: ...bustible Vea No sobrecargue generador Encienda su generador y deje que el motor se estabilice antes de conectar las cargas eléctricas Conecte las cargas eléctricas en la posición de apagado OFF luego encienda ON para su operación Apague OFF las cargas eléctricas y desconéctelas del generador antes de parar el generador El sobrepasar la capacidad del amperaje y vataje del generador puede dañar al g...

Страница 24: ...e del tipo empuje para reposicionar Use cada receptáculo para operar 120 Voltios AC de fase sencilla de cargas de 60Hz que requieren hasta 1 800 vatios 1 8 kW a corrientes de 15 Amps Use los juegos de cables que son calificados para cargas de 125 Voltios AC a 15 Amps o mayores NUNCA intente suministrar corriente a un dispositivo de amperaje superior al que puede suministrar el generador o el enchu...

Страница 25: ...uadamente 4 Conecte y encienda la próxima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga NUNCA añada más cargas sobre la capacidad del generador Tome una atención especial en considerar las cargas de corriente según la capacidad del generador como se describe arriba El vataje que aparece en la lista es solamente una cantid...

Страница 26: ... generador El agua podría introducirse en el sistema de combustible del motor y causar problemas Además si el agua se introduce al generador a través de las ranuras para aire de enfriamiento algo del agua quedará retenida en los espacios vacíos y grietas del aislamiento del devanado del estator y rotor La acumulación de agua y suciedad en los devanados internos del generador disminuirá eventualmen...

Страница 27: ...gasolina le causará problemas Almacene la unidad en un área limpia y seca NO coloque una cubierta encima de un generador caliente Deje que la unidad se enfríe lo suficientemente antes de que le coloque la cubierta Las cubiertas para almacenamiento pueden ser inflamables ADVERTENCIA DIAGNOSITICOS DE AVERÍAS Problemo Accion Causa El motor está funcionando pero no existe salida de AC disponsible 1 El...

Страница 28: ...BO DE COMPRA SI NO APORTA LA PRUEBA DE LA FECHA DE COMPRA INICIAL SE UTILIZARÁ LA FECHA DE FABRICACIÓN DEL PRODUCTO PARA DETERMINAR EL PERÍODO DE GARANTÍA ACERCA DE LA EQUIPO GARANTÍA Esperamos que disfrute de nuestra garantía y le pedimos disculpas por las molestias causadas Cualquier distribuidor de servicio autorizado puede llevar a cabo reparaciones en garantía La mayoría de las reparaciones e...

Отзывы: