Not for
Reproduction
12 www.powerboss-equipment.com
Cord Sets and Receptacles
Use only high quality, well-insulated, grounded
extension cords with the generator’s receptacles.
Inspect extension cords before each use.
Check the ratings of all extension cords before you use
them. Check the operator’s manuals of devices for the
manufacturer’s recommendations.
120 Volt AC, 20 Amp, Duplex Receptacle
The duplex receptacle is protected against overload by
a push to reset circuit breaker.
Use receptacle to operate 120 Volt AC, single–phase,
60 Hz electrical loads requiring up to 1,150 watts
(1.15KW) at 9.6 Amps of current.
NOTICE
Receptacles may be marked with rating
value greater than generator output capacity.
• NEVER attempt to power a device requiring more
amperage than generator or receptacle can supply.
• DO NOT overload the generator. See
Generator Capacity.
WARNING
Damaged or overloaded electrical
cords could overheat, arc, and burn
resulting in death or serious injury.
• ONLY use cords rated for your loads.
• Follow all safeties on electrical cords.
• Inspect cord sets before each use.