POWERBOR Lowprofile 50 Скачать руководство пользователя страница 3

PB50 Low Profile Manual 

Original instructions 

                2019 

 

 

 

1)

 

INTENDED USE 

 
The intended use of this magnetic drill is to drill holes in ferrous metals. The magnet is used to hold the drill in place 
whilst the drill is functioning. It is designed for use in fabrication, construction, railways, petrochemical and any other 
applications when drilling ferrous metal.  
Any deviation from its intended use will not be covered by warranty. 

 

 

2) GENERAL SAFETY RULES

 

 

 

WARNING!

 Read and understand all instructions. Failure to follow all instructions listed below, may result in 

electric shock, fire and/or serious personal injury. 

 

SAVE THESE INSTRUCTIONS. 
 
Work area 

1.

Keep your work area clean and well lit

. Cluttered benchesand dark areas invite accidents. 

2.

Do not operate power tools in explosive atmospheres, suchas in the presence of flammable liquids, gases or 

dust.

Power tools create sparks which may ignite the dust orfumes. 

3.

Keep bystanders, children and visitors away while operatinga power tool. 

Distractions can cause you to lose control 

 

Electrical safety  

1.

Grounded tools must be plugged into an outlet properly installed andgrounded in accordance with all codes and 

ordinances. Neverremove the grounding prong or modify the plug in any way. Do notuse any adaptor plugs. Check 
with a qualified electrician if you are indoubt as to whether the outlet is properly grounded. 

If the tools 

shouldelectrically malfunction or break down, grounding provides a lowresistance path to carry electricity away from 
the user. 
2.

Avoid body contact with grounded surfaces such as pipes, radiators,ranges and refrigerators. 

There is an increased 

risk of electric shock ifyour body is grounded. 
3.

Don’t expose power tools to rain or wet conditions. 

Water entering apower tool will increase the risk of electric 

shock.  
4. 

Do not abuse the cord. Never use the cord to carry the tools or pull the plug from an outlet. Keep cord away from 

heat, oil, sharp edges or moving parts. Replace damaged cords immediately. 

Damaged cords increase the risk of 

electric shock.  
5. 

When operating a power tool outside, use an outdoor extension cord 

marked” W

-A

” 

or

” W”

.

These cords are rated 

for outdoor use and reduce the risk of electric shock.  
 

Personal safety  

1. 

Stay alert, watch what you are doing and use common sense when operating a power tool. Do not use tool while 

tired or under the influence of drugs, alcohol, or medication. 

A moment of inattention while operating power tools 

may result in serious personal injury.  
2. 

Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing, and gloves away 

from moving parts. 

Loose clothes, jewelry, or long hair can be caught in moving parts.  

3. 

Avoid accidental starting. Be sure switch is off before plugging in. 

Carrying tools with your finger on the switch or 

plugging in tools that have the switch on invites accidents.  
4. 

Remove adjusting keys or switches before turning the tool on. 

A wrench or a key that is left attached to a rotating 

part of the tool may result in personal injury.  
5. 

Do not overreach. Keep proper footing and balance at all times. 

Proper footing and balance enable better control of 

the tool in unexpected situations.  
6. 

Use safety equipment. Always wear eye protection. 

Dust mask, non-skid safety shoes, hardhat, or hearing 

protection must be used for appropriate conditions.  

 
Tool use and care  

1.

Use clamps or other practical way to secure and supporttheworkpiece to a stable platform. 

Holding the work by 

Содержание Lowprofile 50

Страница 1: ...Model Number PB50 LOW PROFILE 1 This machine Serial Number is CSA approved G J HALL 830 Hanley industrial court Brentwood Missouri 63144 Tel 314 968 5040 Fax 314 968 5040 Email sales gjhalltools com W...

Страница 2: ...ction Mounting of cutters Remedies for hole making problems Wiring diagram Exploded view Motor Breakdown Control panel and parts list Pipe adapter kit RD2311 Maintenance Trouble shooting Cutter select...

Страница 3: ...of electric shock ifyour body is grounded 3 Don t expose power tools to rain or wet conditions Water entering apower tool will increase the risk of electric shock 4 Do not abuse the cord Never use the...

Страница 4: ...ng of moving parts breakage ofparts and any other condition that may affect the tools operation Ifdamaged have the tool serviced before using Many accidents arecaused by poorly maintained tools 8 Use...

Страница 5: ...ng Capstan fitting 3 15 16 Length Overall including Guard 13 1 8 Nett Weight 24 lbs PB50 LOW PROFILE 1 PB50 LOW PROFILE 3 Vibration total values triax vector sum in accordance with EN62841 1 Vibration...

Страница 6: ...r from the arbor If the machine is accidentally dropped ALWAYS thoroughly examine the machine for signs of damage and check that it functions correctly BEFORE resuming drilling Regularly inspect the m...

Страница 7: ...l AC supply of the correct voltage it is recommended that the following extension lengths shall not be exceeded For 120v supply 3 5metres of 3 core x 2 08mm 14AWG For230v supply 26 yards of 3 core x 1...

Страница 8: ...prove centre punch and or replace worn parts Replace part or parts 3 Excessive drilling pressure required Incorrectly re sharpened worn or chipped cutter Coming down on swarf lying on surface of work...

Страница 9: ...witch And LED 0V White D Motor Switch 0V White E Motor Switch 5V White F Current ON LED 0V White Red G Current ON LED 0V White Green H Current ON LED 5 V White Brown No Function Wire Colour 1 Magnet N...

Страница 10: ...PB50 Low Profile Manual Original instructions 2019 10 11 EXPLODED VIEW OF MACHINE...

Страница 11: ...4006 Screw 1 13 RDF2002 1 Magnet assembly 120v 1 RDF2002 3 Magnet assembly 230v 1 14 RDF4007 Screw 3 15 RDF4008 Screw 2 16 RDF4009 Screw 2 17 RDF3003 Capstan spindle 1 18 RDF4010 Circlip 6 19 RDF2003...

Страница 12: ...bassembly 230v 1 39 RDF2016 2 PCB panel subassembly 120v 1 RDF2016 3 PCB panel subassembly 230v 1 40 RDF4027 Cable jacket 1 41 RDF4028 Jacket 1 42 RDF2024 Cable Plug Assembly 120v 1 RDF2010 3 Cable Pl...

Страница 13: ...1 4 RDF4038 Field Coil Screws 2 5 RDF2019 1 Field Coil Assembly 120v 1 RDF2019 3 Field Coil Assembly 230v 1 6 RDF3015 Motor Frame 1 7 RDF3011 Brush Holder 2 8 RDF3005 1 Carbon Brush Set 120v 1 RDF3005...

Страница 14: ...w Profile Manual Original instructions 2019 14 13 CONTROL PANEL AND PARTS LIST 1 RDC4092 Red Green LED 1 2 RDF4036 Magnet Switch 1 3 RDF4037 Motor Switch 1 4 RDF3008 Facia Plate 1 5 RDF3017 Connection...

Страница 15: ...king care that the magnet is in line with the longitudinal axis of the pipe Switch on the magnet and move the sliding plates down to the outside diameter of the pipe Tighten the screws on both sides b...

Страница 16: ...operation must be checked to ensure that all components are working correctly Machine Brushes should be checked to make sure there is no abnormal wear present this should be checked at least once a we...

Страница 17: ...sound Gear ring bottom of the armature worn out Gear s worn out No grease in gear box Motor humming big sparks and motor has no force Armature damaged Field burned Carbon brushes worn out Motor does n...

Страница 18: ...Steel angle and joists 700N mm M2 Steel angle and joists 850N mm M42 Plate and sheet steel 700N mm M2 Plate and sheet steel 850N mm M42 Aluminium 750Nmm M2 Aluminium 850N mm M42 Brass 700N mm M2 Brass...

Страница 19: ...r S applique aux outils de classe I mis la terre seulement Les outils doubleisolation sont quip s d une fiche polaris e une des lames est plus large que l autre qui ne peut se brancher que d une seule...

Страница 20: ...s pr ventives de s curit r duisent le risque de d marrage accidentel de l outil Rangez les outils hors de la port e des enfants et d autres personnes inexp riment es Les outils sont dangereux dans les...

Отзывы: