background image

Troubleshooting

Please read th

ese

 section

s

 for troubleshooting before requesting repair services.

Trouble

Indicator status

No light

Lights on

See below

No dry air blow when hands put in.

Power Switch might be set to OFF

If so, set Power Switch to ON.

Has the circuit breaker been tripped?

If is OFF, Please reset it.

See page 3

Due to the location of Sensors, detection of hands is difficult in some 
areas, including between Sensors and near the corners

Align fingers and put both hands fully into drying compartment . 
If air blows,the dryer is working properly.

Has Filter accumulated dust or debris?

Clean Filter if these is an accumulation of dust or debris.

Is the ambient temperature within opetating temperature limits?

Set the temperature within 

 -1

0 to 4

0

℃。

Has something been placed inside the unit that could be blocking a sensor?

If there is something in the unit, remove it.

Is the sensor dirty?

If the sensor is not clean, wipe it with a soft damp cloth.

If the problem persists after the sensor is cleaned, the sensor is malfunctioning.

soltuions

Dryer not stopped when
hands removed

Warm air is not blown

Warm air is blown

The air volume is weak

Stopping 1-2 seconds after removing hands is normal.

Is the sensor dirty?

If the sensor is not clean, wipe it with a soft damp cloth.

Heater Power Switch might be set to OFF.

If so, set Heater Power Switch to ON.

Is the ambient temperature low?

The air might feel colder when the temperature is low.

(Only for the unit with aheater)Heater Power Switch might be set to ON.

If so, set Heater Power switch to OFF

Has Filter accumulated dust or debris?

Clean Filter if dust or debris has accumulated.

Is the ambient temperaure high?

The air might feel warmer when the temperature is high.

Is the dryer active for along time?

The air might become wamer if hand dryer is active for a long time 
due to heat from the fan motor. 

Clean filter if it has accumulated dust or debris.

Is the Fan Strength Switch set to Low?

Set the Fan Strength to High.

If the problem still prosists after preforming suggested actions, turn off the power switch and set 
the breaker to

 

Off.

 

Please contact the supplier.

(only for units with a heater)

 Light was flashing

Has Filter accumulated dust or debris?

 Light was flashing

See below

See page 

2

See page 

3

See page 3

See page 

10

See page 

10

See page 3

See page 

2

11

Содержание PW-70-3

Страница 1: ...lation and operation This manual should be kept for future reference Safety Cautions Spare Parts Dimension Drawing Functional Introduction How to use Maintenance Troubleshooting Specifications 1 2 2 4 9 10 11 12 13 6 8 Introduction How to use Maintenance Troubleshooting Installation procedures Installation procedures 3 Electrical wiring diagram 5 ...

Страница 2: ...ct into Air nozzles Doing so could result in burns or other product problems Before cleaning turn off the power switch Failure to do so could result in sudden activation of the unit or electrical shock CAUTION REQUESTS Use water resistant material for nearby walls or floor as small water drops may spread about if a user moves hands violently when drying hands Do not squirt water on the main dryer ...

Страница 3: ...ing switch Sensor Indicator light Vent LED light HEPA filter FULL line Water level indicator lamp Dimension Drawing 2 2 9 5 2 6 5 5 3 0 1 6 0 1 8 0 2 6 0 1 9 0 No spill water channel HEPA Filter Drain tank Power cord mm ...

Страница 4: ...Mode Power off Power on High speed Low speed Heater off Heater on 3 Switch Functional Introduction ...

Страница 5: ... user moves hands violently when drying hands The hand dryer stops automatically after approxinmaterly 30 second of continuous operation In order to continue to use the product remove hands again Ouststretch fingers and insert hands all the way into the product Afert the dryer is activated slowly lift hands white water is blown off 4 ...

Страница 6: ...wer supply other than specified Otherwise a fire could result Do not damage power line Continued use of a unit with a damaged line could cause fire eleceric shock or product problems Electric work must be done by qualified personel following Technical Standards of Electric Equipment Indoor wiring requlations and the Installion Guide Improper wiring could cause fire to ignite Install an earth leaka...

Страница 7: ...h a sufficient current rating and rating and apply the specified power Earth leakage circuit breaker Power supply Rated 10 A or more AC220 240V 20 20 40 To Installaton Contractors After verifying the trial operation give the customer the Instruction Manual and Cleaning Instruction Sheet and explain how to use the product Instruction Manual Four screws mm Instruction Manual Mounting plate Four tube...

Страница 8: ...n of the base plate Height of the installation of the base plate For Man 900mm For Woman 870mm For disabled 800mm For Children 700mm 3 The location of power line 500mm 200mm 40mm 认电源线长度 4 The length of the power line 5 Install the machine 7 ...

Страница 9: ...6 Installation of Anti theft screw 7 Install filter screen 8 Confirm the switch position Lighting 9 Test operation 10 Installation drain tank Lock 8 ...

Страница 10: ...oing so could result in electrical shock or other product problems Do not install the water tray with cleaning agent residue into the product Doing so could cause product problems Before cleaning turn off the power switch Failure to do so could result in sudden activation of the product Do not use acid or alkali chemicals designde for cleaning toiltes Do not use benzine thinners or cleansers Do no...

Страница 11: ...3 Drain tank 1 2 3 4 5 6 7 8 HEPA Filter Once every 100 days to 150 days 4 Take out the HEPA filter and replace it FULL line Cleaning filter box When the water is full clean it in time 10 ...

Страница 12: ...pped when hands removed Warm air is not blown Warm air is blown The air volume is weak Stopping 1 2 seconds after removing hands is normal Is the sensor dirty If the sensor is not clean wipe it with a soft damp cloth Heater Power Switch might be set to OFF If so set Heater Power Switch to ON Is the ambient temperature low The air might feel colder when the temperature is low Only for the unit with...

Страница 13: ...n If they are not clean wipe them with a soft damp cloth Water tray is full Discard water from the water tray If the indicator does not turn off consult with the installion contractor ON OFF Always On ON OFF Always ON ON OFF Light was flashing Nomal state Standby The dryer is activated Power ON Abnormal state Flashing Flashing ON OFF Light was flashing LED Light Meaning or the indicators Operation...

Страница 14: ... range Heater on Heater off High speed Low speed Power consumption 13 10 Kg Description High Speed Hand Dryer AC220V 240V 50Hz 60Hz Directly connect to power supply 2000W 1300W 1500W 1100W Approximately 2 3W or lower AC brush motor PTC Temperature sensor current fuse temperature fuse Width 300mm depth 165mm height 535mm Approximately 1200mL Between 10 40 Set a temperature that prevents condensatio...