Power works RS 15 A SUB Скачать руководство пользователя страница 2

Important Safety Instructions

Before connecting, read instructions

• Read all of these instructions!
• Save these instructions for later use!
• Follow all warnings and instructions marked on the product!
• Do not use this product near water, i.e. bathtub, sink, swimming pool, 

wet basement, etc.

• Do not place this product on an unstable cart, stand or table. The product may fall,

causing serious damage to the product or to persons!

• Slots and openings in the cabinet and the back or bottom are provided for ventilation; to

ensure reliable operation of the product and to protect it from overheating, these openings
must not be blocked or covered. This product should not be placed in a built-in installation
unless proper ventilation is provided.

• This product should not be placed near a source of heat such as a stove, 

radiator, or another heat producing amplifier.

• Use only the supplied power supply or power cord. If you are not sure of the type of power

available, consult your dealer or local power company.

• Do not allow anything to rest on the power cord. Do not locate this product where per-

sons will walk on the cord.

• Never break off the ground pin on the power supply cord.
• Power supply cords should always be handled carefully. Periodically check cords for cuts or

sign of stress, especially at the plug and the point where the cord exits the unit.

• The power supply cord should be unplugged when the unit is to be unused for long

periods of time.

• If this product is to be mounted in an equipment rack, rear support should be provided.
• This product should be used only with a cart or stand that is recommended by

HK AUDIO

®

.

• Never push objects of any kind into this product through cabinet slots as they may touch

dangerous voltage points or short out parts that could result in risk of fire or electric
shock. Never spill liquid of any kind on the product.

• Do not attempt to service this product yourself, as opening or removing covers may

expose you to dangerous voltage points or other risks. Refer all servicing to qualified
service personnel.

•  Clean only with dry cloth.
•  Do not defeat the safety purpose of the polarized or grounding-type plug. 

A polarized plug has two blades with one wider than the other. A grounding type plug has
two blades and a third grounding prong. The wide blade or the third prong are provided
for the safety. If the provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.

• Unplug this product from the wall outlet and refer servicing to qualified service personnel

under the following conditions:

• When the power cord or plug is damaged or frayed.
• If liquid has been spilled into the product.
• If the product has been exposed to rain or water.
• If the product does not operate normally when the operating instructions are followed.
• If the product has been dropped or the cabinet has been damaged.
• If the product exhibits a distinct change in performance, indicating a need of service!
• Adjust only these controls that are covered by the operating instructions since improper

adjustment of other controls may result in damage and will often require extensive work
by a qualified technician to restore the product to normal operation.

• Exposure to extremely high noise levels may cause a permanent hearing loss. 
• Individuals vary considerably in susceptibility to noise induced hearing loss, but nearly

everyone will lose some hearing if exposed to sufficiently intense noise for a sufficient
time. The U.S. Government´s Occupational Safety and Health Administration (OSHA) has
specified the following permissible noise level exposures:

Duration Per Day In Hours

Sound LeveldBA, Slow Response

8

90

6

92

4

95

3

97

2

100

11/2

102

1

105

1/2

110

1/4  or less

115

• According to OSHA, any exposure in excess of the above permissible limits could result in

some hearing loss.

• Ear plug protectors in the ear canals or over the ears must be worn when operating this

amplification system in order to prevent a permanent hearing loss if exposure is in excess of
the limits as set forth above. To ensure against potentially dangerous exposure to high
sound pressure levels, it is recommended that all persons exposed to equipment capable
of producing high sound pressure levels such as this amplification system be protected by
hearing protectors while this unit is in operation.

• Fuses: Replace with IEC 127 (5x 20 mms) type and rated fuse for best 

performance only.

TO PREVENT THE RISK OF FIRE AND SHOCK HAZARD, DO NOT EXPOSE THIS
APPLIANCE TO MOISTURE OR RAIN. DO NOT OPEN CASE; 
NO USER SERVICE-ABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

Important Advice on Safety!

Please read before use and keep for later use!

• The unit has been built by HK AUDIO

®

in accordance with IEC 60065 and left the factory

in safe working order. To maintain this condition and ensure non-risk operation, the user
must follow the advice and warning comments found in the operating instructions. The
unit conforms to Protection Class 1 (protectively earthed).

• HK AUDIO

®

ONLY GUARANTEE THE SAFETY, RELIABILITY AND EFFICIENCY OF THE

UNIT IF:

• Assembly, extension, re-adjustment, modifications or repairs are carried out by

HK AUDIO

®

or by persons authorized to do so.

• The electrical installation of the relevant area complies with the requirements of IEC

(ANSI) specifications.

• The unit is used in accordance with the operating instructions.
• The unit is regularly checked and tested for electrical safety by a competent technician.

WARNING:

• If covers are opened or sections of casing are removed, except where this can be done

manually, live parts can become exposed.

• If it is necessary to open the unit this must be insulated from all power sources. Please

take this into account before carrying out adjustments, maintenance, repairs and before
replacing parts.

• The appliance can only be insulated from all power sources if the mains connection is

unplugged.

• Adjustment, maintenance and repairs carried out when the unit has been opened and is

still live may only be performed by specialist personnel who are authorized by the
manufacturer (in accordance with VBG 4) and who are aware of the associated hazards.

• Loudspeaker outputs which have the IEC 417/5036 symbol (Diagram 1, below) can carry

voltages which are hazardous if they are made contact with. Before the unit is switched
on, the loudspeaker should therefore only be connected using the lead recommended by
the manufacturer.

• Where possible, all plugs on connection cables must be screwed or locked onto the

casing.

• Replace fuses only with IEC127 type and specified ratings.
• It is not permitted to use repaired fuses or to short-circuit the fuse holder.
• Never interrupt the protective conductor connection.
• Surfaces which are equipped with the "HOT" mark (Diagram 2, below), rear panels or

covers with cooling slits, cooling bodies and their covers, as well as tubes and their covers
are purposely designed to dissipate high temperatures and should therefore not be
touched.

• High loudspeaker levels can cause permanent hearing damage. You should 

therefore avoid the direct vicinity of loudspeakers operating at high levels. 
Wear hearing protection if continuously exposed to high levels.

MAINS CONNECTION:

• The unit is designed for continuous operation.
• The set operating voltage must match the local mains supply voltage.
• The unit is connected to the mains via the supplied power unit or power cable.
• Power unit: Never use a damaged connection lead. Any damage must be rectified by a

competent technician.

• Avoid connection to the mains supply in distributor boxes together with several other

power consumers.

• The plug socket for the power supply must be positioned near the unit and must be easily

accessible.

PLACE OF INSTALLATION:

• The unit should stand only on a clean, horizontal working surface.
• The unit must not be exposed to vibrations during operation.
• Keep away from moisture and dust where possible.
• Do not place the unit near water, baths, wash basins, kitchen sinks, wet areas, swimming

pools or damp rooms. Do not place objects containing liquid on the unit - vases, glasses,
bottles etc.

• Ensure that the unit is well ventilated.
• Any ventilation openings must never be blocked or covered. The unit must be positioned

at least 20 cm away from walls. The unit may only be fitted in a rack if adequate
ventilation is ensured and if the manufacturer's installation instructions are followed.

• Keep away from direct sunlight and the immediate vicinity of heating elements and

radiant heaters or similar devices.

• If the unit is suddenly moved from a cold to a warm location, condensation can form

inside it. This must be taken into account particularly in the case of tube units. Before
switching on, wait until the unit has reached room temperature.

• Accessories: Do not place the unit on an unsteady trolley, stand, tripod, base or table. If

the unit falls down, it can cause personal injury and itself become damaged. Use the unit
only with the trolley, rack stand, tripod or base recommended by the manufacturer or
purchased together with the unit. When setting the unit up, all the manufacturer's
instructions must be followed and the setup accessories recommended by the manu-
facturer must be used. Any combination of unit and stand must be moved carefully. 
A sudden stop, excessive use of force and uneven floors can cause the combination of unit
and stand to tip over.

• Additional equipment: Never use additional equipment which has not been recommended

by the manufacturer as this can cause accidents.

• To protect the unit during bad weather or when left unattended for prolonged periods, the

mains plug should be disconnected. This prevents the unit being damaged by lightning
and power surges in the AC mains supply.

Diagram 1

Diagram 2

RS 15 Sub A BDA 1.1  30.08.2004 13:30 Uhr  Seite 2    (Schwarz Bogen)

Version 1.0  10/2004

Содержание RS 15 A SUB

Страница 1: ...BEDIENUNGSANLEITUNG ENGLISH DEUTSCH FRANÇAIS ESPAÑOL MANUAL RS 15 Sub A 1 1 ...

Страница 2: ...actory in safe working order To maintain this condition and ensure non risk operation the user must follow the advice and warning comments found in the operating instructions The unit conforms to Protection Class 1 protectively earthed HK AUDIO ONLY GUARANTEE THE SAFETY RELIABILITY AND EFFICIENCY OF THE UNIT IF Assembly extension re adjustment modifications or repairs are carried out by HK AUDIO o...

Страница 3: ...bei Gewitter oder wenn es längere Zeit nicht beaufsichtigt oder benutzt wird sollte der Netzstecker gezogen werden Dies verhindert Schäden am Gerät aufgrund von Blitzschlag und Spannungsstößen im Wechselstromnetz Abb 1 Abb 2 Conseils de Securite Importants Priere de lire avant l emploi et a conserver pour utilisation ulterieure L appareil a été conçu par HK AUDIO selon la norme IEC 60065 et a quit...

Страница 4: ...enti Per proteggere l apparecchio in caso di temporali o nel caso questo non venisse utilizzato per diverso tempo si consiglia di staccarne la spina di corrente In questo modo si evitano danni all apparecchio dovuti a colpi di fulmine o ad improvvisi aumenti di tensione nel circuito di corrente alternata Illustrazione 1 Illustrazione 2 Indicaciones de seguridad importantes Léanse antes de utilizar...

Страница 5: ...controls its sensitivity enabling you to adjust the RS 15 Sub A s power amps to match the given input signal level Note If you want to operate the RS 15 Sub A in mono mode you must patch the mono input signal through to the second input of the RS 15 Sub A using a microphone cord In other words connect the cord from the Through port of the input that you re using to the second input This is the onl...

Страница 6: ...n Zu jedem der beiden Eingänge gibt es einen Gain Regler für die Eingangsempfindlichkeit um die Endstufen des RS 15 Sub A optimal an die Pegel des Eingangssignals anzupassen Hinweis Sollen die Satelliten Verstärker des RS 15 Sub A mono betrieben werden muß das Mono Eingangssignal mit einem Mikrokabel auf den zweiten Eingang des RS 15 Sub A durchgeschleift werden d h aus dem Through des benutzten E...

Страница 7: ... utilisé en mono Les deux entrées sont équipées d un potentiomètre GAIN pour la sensibilité d entrée afin d adapter les étages de puissance du RS 15 Sub A de manière optimale au niveau du signal d entrée Nota Si l amplificateur satellite du RS 15 Sub A doit être utilisé en mono il faut que le signal d entrée mono soit bouclé par un câble pour microphone sur la deuxième entrée du RS 15 Sub A c est ...

Страница 8: ... de las dos entradas existen un regulador de ganacia para la sensiblidad de entrada con el objeto adaptar las etapas de potencia del RS 15 Sub A optima mente al nivel de la señal de entrada Nota Si se han de utilizar los amplificadores satélites del RS 15 Sub A en modo mono se ha de conectar de paso la señal de entrada Mono con un cable de micro en la segunda entrada del RS 15 Sub A es decir desde...

Страница 9: ...9 RS 15 Sub A Manual 1 1 ...

Страница 10: ...tput subwoofer Mono 300 W 8 ohms at 1 THD Power output each satellite 150 W 4 ohms at 1 THD Speaker 1x 15 HK Audio Custom Sensitivity 1W 1m axial 104 dB half space Max sound pressure 123 dB at 10 harmonic distortion half space 1m Dimensions weight Width 540 mm Height 440 mm Depth 615 mm Weight 37 kg General electrical data Protection Class 1 protectively earthed Max current consumption 4 1 A 230 V...

Страница 11: ...ng wird verantwortlich für den Hersteller abgegeben durch Lothar Stamer Dipl Ing Geschäftsführer St Wendel den 25 03 04 Stamer Musikanlagen stellt exklusiv für POWERWORKS her Stamer Musikanlagen GmbH Magdeburger Str 8 66606 St Wendel This is to certify that POWERWORKS RS 15 SUB A complies with the provisions of the Directive of the Council of the European Communities on the approximation of the la...

Страница 12: ...en Copyrights 2004 Music Sales GmbH 09 2004 MS D 1140 09 04 PowerWorks Postfach 1509 66595 St Wendel Germany info powerworksaudio de www powerworksaudio de International Inquiries fax 49 68 51 905 215 international powerworksaudio de ...

Отзывы: