4
Installation and setup
1.
Install the regulator and wire up to the correct wiring diagram.
2.
Turn the internal voltage control and stability control 15 or more turns counter
clockwise (left). This procedure is necessary in case the original factory settings
have been altered.
3.
If you are using a remote voltage adjustment, set it at 50% of adjustment.
4.
Start up the prime mover and bring up to operating speed and turn on the
regulator switch. (if used)
5.
Set the internal voltage adjustment to the desired voltage setting for the
generator output. If the generator voltage is unsteady or flickering, adjust the
stability adjustment clockwise (right) until the voltage is steady and the green
light is not pulsating. During this adjustment, be sure to keep the generator
voltage within 10vac of the original setting with the internal voltage adjustment.
6.
Place the generator on line and observe the frequency and voltage.
Internal
voltage
adjustment
Stability
adjustment