Specifications: 

Input Voltage  

190 to 250vac, single phase 

Output Amperage  200adc continuous 
Type Regulation 

Flat response/VPH 

Protection 

 

Internal fusing 

Physical Size  

24 x 30 x 12 in 

Weight 

 

50 lbs 

Voltage Regulator  XR500D 
Build up module 

AFM500X 

Build up voltage 

6.5vac 

 
 
 
 
 

The SE2000BX Static Exciter is designed to 
replace most electronic, saturable reactor and 
rotary exciters used on slip ring or rotor fed 
electric generators.  The SE2000BX offers 
unique features such as a remote mounted 
control panel and easy serviceability in the 
field.  The input power and voltage sensing 
for the SE2000BX are taken directly from the 
generator AC stator and rectified into a 
controllable DC input to the main generator 
rotor.  The SE2000BX is a complete static 
exciter that includes the voltage regulator, 
power fusing, surge suppression, build up 
module and connection terminals.  Optional 
devices are offered for the SE2000BX such 
as an interface card, which allows the 
SE2000BX to be controlled with power factor 
controllers and other types of genset and PLC 
controllers.  The SE2000BX has provisions 
for parallel operation. 
 

SE2000BX Static Exciter 

Содержание SE2000BX

Страница 1: ...ing or rotor fed electric generators The SE2000BX offers unique features such as a remote mounted control panel and easy serviceability in the field The input power and voltage sensing for the SE2000BX are taken directly from the generator AC stator and rectified into a controllable DC input to the main generator rotor The SE2000BX is a complete static exciter that includes the voltage regulator p...

Страница 2: ...ondition 4 Mount exciter onto a cabinet or housing You can mount the regulator control assembly in another location for safety and ease of operation 5 Install 190 to 240vac single phase to the AC1 and AC2 terminals of the static exciter Fig A It is highly recommended that a disconnect switch or breaker is placed between the generator stator and the static exciter for emergency purposes 6 Install t...

Страница 3: ... 830 895 4700 Fax 830 895 4703 Email pti power tronics com Internet www power tronics com 240vac from generator F to main rotor F to main rotor Safety Disconnect Switch Main power input and field wiring diagram Figure A Removable Control Panel SE2000BX ...

Страница 4: ...mounted in a location away from the main exciter assembly for safety and operator use The relocation should be as close to the exciter assembly as possible Control Wiring Figure B B D E F TB3 Isolated Battery 12 24V Customer Supplied DPST N O Switch 45 Amp Diode 800V Regulator off on Switch 1000 ohm 1 2 watt Remote Voltage Adjustment XR500D Universal Voltage Regulator Use battery flash only if nee...

Страница 5: ...n of the SE2000BX A B C GENERATOR 240vac AC1 AC2 Unit Parallel Switch Droop Adjustment 6Ω 100w 5 amp CT A B C D E F TB3 X Y SE2000BX Generator voltage should droop during starting of an inductive load if it rises reverse the X and Y connections Always close the Unit Parallel switch during non parallel operation of the generator The current transformer must be totally isolated from all other circui...

Страница 6: ...he voltage control panel for use with the UIC200 Universal Interface Module You can use either a 5vdc or 10vdc or 0 5vdc or 0 10vdc input from either an analog or digital signal from an external source such as a power factor controller genset controller or PLC Refer to the UIC200 instruction manual for complete details Manual Automatic Selector 100K D E UIC200 E F Remote Voltage Adjustment ...

Страница 7: ...t which clearly shows the purchase date and serial number of the defective part A repair request form must be sent in with the product before repairs will begin You can obtain this form through contacting Power Tronics Inc Send repairs to Power Tronics Inc 2802 Cobbler Ln Kerrville Texas USA 78028 Send in repairs only by UPS or FedEx Any one of the following conditions will void the warranty Overh...

Отзывы: