GENERAL DESCRIPTION

This unit is a two stage, constant current battery charger for charging nickel cadmium type 
rechargeable batteries. The charge termination is by timer (13 to 15 hours standard) at 
which time it will switch from the charge current into a float charge mode at a reduced 
current. An output cable, 6 feet long, with a barrel plug is provided. There are two 
indicators on the front panel. The orange light indicates that the charger is in the charging 
mode. The green light indicates that the battery is fully charged. 

ASSEMBLY INSTRUCTIONS 

Loosen the screws on the charger output terminal                       
strip. Identify the polarity of the terminal strip and  
the output connector; both the charger housing  
and the output cable are marked with "+" & "-"  
symbols. Attach the two spade terminals to the  
terminal strip and tighten the screws. To prevent  
accidental shorting, cover the exposed terminals  
with the molded press-on terminal cover. 
Loosen the screws on the charger output terminal                 

OPERATING INSTRUCTIONS 

Before using this battery charger, make sure it is compatible with your battery. Refer to the 
ratings on the battery charger, the specifications in this manual, and your battery 
documentation. Charge only nickel cadmium and nickel metal hydride type rechargeable 
batteries. Attempting to charge other types of batteries may result in battery damage. This 
unit is provided with a polarized barrel plug connector. Make sure your battery connector is 
wired to match the output connector. 

CAUTION!

This unit is not reverse battery protected except by use of the polarized 

connector. Make sure your battery connector is wired to match the charger connector or 
damage to the battery and charger may result when power is applied. While in a reversed 
condition the charger will indicate that it is in the charging mode. However, it will actually 
be discharging the battery at the rated charge current until either the battery or charger is 
damaged.

CAUTION!

This unit is not short circuit protected - it will deliver the full rated current into a 

short. If the short is not removed, the charger may overheat and be damaged. While in a 
shorted condition the charger will indicate that it is in the charging mode. If the charging 
light is on while not connected to a battery then there is probably a short in the output 
cable or connector. Remove the output cable to see if the charge light goes out. If the light 
stays on without an output cable connected then there is a problem with the charger.

Plug the battery charger  into a properly grounded (3-prong) wall outlet which supplies the 
correct input power as marked on the unit. The indicators should be dark until a battery is 
attached.

Attach the output connector to the battery connector. The charger should now be on and 
charging the battery. The orange CHARGING light should be on. If the green READY light is 
on instead, then the battery voltage is probably too high (too many cells). The battery must 
be a 1.2 to 14.4 volts (1 to 12 cells) battery. 

The orange CHARGING light indicates that the charger is on and in the charging mode. The 
charger will deliver a constant current (rated output current) to the battery for 13 to 15 
hours. After this time, the unit will switch into the float charge mode - the orange 

Содержание PSN Series

Страница 1: ...N Series Operating Instructions WARNING CONCERNING THE REMOVAL OF COVER CAUTION TO PREVENT THE RISK OF CAUTION TO PREVENT FIRE OR SHOCK ELECTRIC SHOCK DO NOT REMOVE HAZARD DO NOT EXPOSE UNIT TO RAIN COVER NO USER SERVICEABLE PARTS OR MOISTURE INSIDE REFER SERVICE TO QUALIFIED SERVICE PERSONNEL ...

Страница 2: ...ng off controls may not reduce this risk WARNING Charge only nickel cadmium and nickel metal hydride type rechargeable batteries Attempting to charge other types of batteries may result in personal injury and battery damage The enclosure metal face may become hot during the charge cycle DO NOT TOUCH DANGER Never alter power plug blades or ground pin If it will not fit the outlet have a proper outl...

Страница 3: ...ry protected except by use of the polarized connector Make sure your battery connector is wired to match the charger connector or damage to the battery and charger may result when power is applied While in a reversed condition the charger will indicate that it is in the charging mode However it will actually be discharging the battery at the rated charge current until either the battery or charger...

Страница 4: ...2800 10 Refer to your battery documentation to see if the charger will charge your battery properly Example If your charger is rated for 400 mA then it will recharge 4 AHr batteries between 4 8 to 13 2 volts 4 to 11 cells It will safely charge a 14 4 volt 12 cells battery as long as the charger receives a full 115 volts ac input If the input voltage is below 115 volts at that charge voltage the ma...

Страница 5: ...ption A power outage or glitch may have reset the charger timer for another 13 to 15 hour charge cycle CHARGE LIGHT ON WITHOUT A BATTERY This indicates that the output cable or connector is shorted If the light goes out with the output cable removed then you should replace the cable Do not attempt to charge a battery with a shorted output cable RATTLE If you think you hear a rattle inside the char...

Отзывы: