9
Parallel kit terminal
It used for parallel operation with another inverter (parallel kit sold separately)
Running indicator (green)
The running indicator lights up when generating set starts and has normal output.
Overload indicator (red)
When the overload indicator is on, it indicates that the generating set is overload and it may cause
overheat of frequency converter, or increase of AC voltage. And then the AC protector works. It will stop
the output of generating set to protect the electric equipment and the generating set itself. At this time, the
running indicator (green) is off and the overload indicator (red) is on, but the engine is still in running
state.
When the generating set has no output and the overload indicator is on, please take the following steps:
1. Lower the total power of the connected electric devices to the rated output range of generating set.
2. Check the air intake for impurities and check the control parts for abnormal situation. Handle
immediately if necessary.
3. Press the reset button.
Oil alarm lamp (yellow)
When the oil level drops below the lower limit, the oil protection system will stop the engine
automatically and oil alarming lamp will blink by pulling the recoil starter. The engine will not run until
the oil has been filled to the proper level.
Note:
If engine flames out or fails to start, please adjust Engine switch to “ON” position and then pull the
recoil starter. If the oil alarming lamp lights up, it shows lack of oil. Please add appropriate oil and restart
the engine.