![Power smart PS3030 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/power-smart/ps3030/ps3030_instruction-manual_1587672018.webp)
18
Problem
Possible Cause
Possible Solution
Excessive
Vibration
1. Improper base mounting.
2. Unsuitable mounting surface.
3. Loose motor mounting.
1. Make sure mounting hardware is secure.
2. The heavier the work bench, the
less vibration will occur.
3. Check that motor mounting hardware is
secure.
Blade not in line
with arm motion
Blade holders not aligned.
Loosen hex bolts and re-align upper and
lower blade holders. Tighten hex bolts.
Tool will not start
1. Power cord not connected.
2. No power at outlet.
3. Tool’s thermal reset breaker
tripped (if equipped).
4. Internal damage or wear.
(Carbon brushes or switch, for
example.)
1. Check that cord is plugged in.
2. Check power at outlet. If outlet is
unpowered, turn off tool and check circuit
breaker.
If breaker is tripped, make sure circuit is
right capacity for tool and circuit has no
other loads.
3. Turn off tool and allow to cool. Press
reset button on tool.
4. Have technician service tool.
Tool operates
slowly
Extension cord too long or wire
size too small.
Eliminate use of extension cord. If an
extension cord
is needed, use one with the proper diameter
for its length and load.
Performance
decreases over
time
1. Saw blade dull or damaged.
2. Carbon brushes worn or
damaged.
1. Replace saw blade.
2. Have qualified technician replace
brushes.
Excessive noise
or rattling
Internal damage or wear.
(Carbon brushes or bearings, for
example.)
Have technician service tool.
Overheating
1. Forcing machine to work too
fast.
2. Saw blade dull or damaged.
3. Blocked motor housing vents.
4. Motor being strained by long
or small diameter extension
cord.
1. Allow machine to work at its own rate.
2. Replace saw blade.
3. Wear ANSI-approved safety goggles
and
NIOSH-approved dust mask/respirator
while blowing dust out of motor using
compressed air.
4. Eliminate use of extension cord.
If an extension cord is needed, use one
with the proper diameter for its length and
load.
WARNING:
Follow all safety precautions whenever diagnosing or servicing the tool.
Disconnect power supply and remove the Safety Key before service.