46
3.
Press the start button
for one second
and after release it. The generator
performs a starting sequence automatically.
NOTE:
Do not keep the start button pressed. Just press for a second,
approximately.
If the generator does not start on the first attempt, the generator will do 2 more
attempts automatically. Just wait.
If it doesn't start in the first 3 attempts, you can press the start button again to start
a new starting sequence.
NOTE:
This generator is equipped with an automatic choke system, so that no
lever is needed to make easy a first starting (cold condition).
Information:
OPD Function
(Output power delayed). Up to 20 seconds after the
starting, the generator does not generate electricity in the 230V socket. This
ensures that the generator starts without supplying power to the connected
equipment.
Information:
The battery may be weak if the generator was storage for a long
time.
If the battery is weak, the generator must be started manually (see chapter
5.1). Automatically, during the running, the battery is charged.