1-5. Maintenance, service and faults 

 

The UPS system operates with hazardous voltages. Repairs may be carried out only by 
qualified maintenance personnel.   

 

Caution - 

risk of electric shock. Even after the unit is disconnected from the mains 

(building wiring outlet), components inside the UPS system are still connected to the 
battery and electrically live and dangerous.   

 

Before carrying out any kind of service and/or maintenance, disconnect the batteries 
and verify that no current is present and no hazardous voltage exists in the terminals of 
high capability capacitor such as BUS-capacitors.   

 

Only persons are adequately familiar with batteries and with the required precautionary 
measures may replace batteries and supervise operations. Unauthorized persons must 
be kept well away from the batteries.   

 

Caution -

 risk of electric shock. The battery circuit is not isolated from the input 

voltage. Hazardous voltages may occur between the battery terminals and the ground. 
Before touching, please verify that no voltage is present!   

 

Batteries may cause electric shock and have a high short-circuit current. Please take 
the precautionary measures specified below and any other measures necessary when 
working with batteries:   

remove wristwatches, rings and other metal objects   

use only tools with insulated grips and handles.   

 

When changing batteries, install the same number and same type of batteries.   

 

Do not attempt to dispose of batteries by burning them. This could cause battery 
explosion.   

 

Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin and 
eyes. It may be toxic.   

 

Please replace the fuse only with the same type and amperage in order to avoid fire 
hazards.   

 

Do not dismantle the UPS system. 

 
 
 

 
 
 

 
 
 
 

 
 
 

 
 
 
 

Содержание VFI-C Series 1KR

Страница 1: ...VFI C Series 1K 2K 3K Online UPS Uninterruptible Power Supply System Version 1 1...

Страница 2: ...2 2 Installation and setup 3 2 1 Rear panel view 3 2 2 Setup the UPS 7 3 Operations 9 3 1 Button operation 9 3 2 LCD Panel 9 3 3 Audible Alarm 11 3 4 LCD display wordings index 11 3 5 UPS Setting 11...

Страница 3: ...er them Do not connect domestic appliances such as hair dryers to UPS output sockets The UPS can be operated by any individuals with no previous experience Connect the UPS system only to an earthed sh...

Страница 4: ...must be kept well away from the batteries Caution risk of electric shock The battery circuit is not isolated from the input voltage Hazardous voltages may occur between the battery terminals and the...

Страница 5: ...thing inside the package is damaged Please keep the original package in a safe place for future use 2 1 Rear panel view 1K India Type IEC Type NEMA Type Schuko Type Universal Type 1KL India Type IEC T...

Страница 6: ...4 2KL India Type IEC Type Schuko Type Universal Type 3K India Type IEC Type NEMA Type Schuko Type Universal Type 3KL India Type IEC Type Schuko Type Universal Type 1KR IEC Type Universal Type...

Страница 7: ...5 China Type 2KR IEC Type Universal Type China Type 3KR IEC Type Universal Type China Type 1KRL IEC Type Universal Type...

Страница 8: ...Universal Type China Type 1 AC input 2 Input circuit breaker 3 USB communication port 4 RS 232 communication port 5 SNMP intelligent slot option 6 External battery connection only available for L mod...

Страница 9: ...status monitoring connect the communication cable one end to the USB RS 232 port and the other to the communication port of your PC With the monitoring software installed you can schedule UPS shutdown...

Страница 10: ...8 Step 6 External battery connection This UPS is not including batteries Please connect external batteries as below chart...

Страница 11: ...in standby mode under power normal or transfer to Bypass mode if the Bypass enable setting by pressing this button Confirm selection key Press this button to confirm selection in UPS setting mode Sele...

Страница 12: ...frequency Load information Indicates the load level by 0 25 26 50 51 75 and 76 100 Indicates overload Indicates the load or the UPS output is short circuit Mode operation information Indicates the UP...

Страница 13: ...re CH Charger FU Bypass frequency unstable EE EEPROM error 3 5 UPS Setting There are three parameters to set up the UPS Parameter 1 It s for program alternatives Refer to below table Parameter 2 and p...

Страница 14: ...t frequency is 60Hz If converter mode is enabled you may choose the following output frequency CF 50 presents output frequency is 50Hz CF 60 presents output frequency is 60Hz 04 ECO enable disable Int...

Страница 15: ...in parameter 3 from 230Vac to 264Vac Default 264Vac For 100 110 115 120 127 VAC models 115 132 setting the high voltage point in parameter 3 from 115Vac to 132Vac Default 132Vac LLS Bypass low voltage...

Страница 16: ...er mode When input frequency is within 40 Hz to 70 Hz the UPS can be set at a constant output frequency 50 Hz or 60 Hz The UPS will still charge battery under this mode Battery mode When the input vol...

Страница 17: ...ltage high 12 x Charger failure 45 x Inverter voltage Low 13 x 3 8 Warning indicator Warning Icon flashing Alarm Low Battery Sounding every second Overload Sounding twice every second Battery is not c...

Страница 18: ...e every second UPS is overload Remove excess loads from UPS output UPS is overloaded Devices connected to the UPS are fed directly by the electrical network via the Bypass Remove excess loads from UPS...

Страница 19: ...up time is shorter than nominal value Batteries are not fully charged Charge the batteries for at least 5 hours and then check capacity If the problem still persists consult your dealer Batteries defe...

Страница 20: ...ler Storage Before storing charge the UPS 5 hours Store the UPS covered and upright in a cool dry location During storage recharge the battery in accordance with the following table Storage Temperatur...

Страница 21: ...1 Harmonic Distortion 3 THD linear load 6 THD non linear load Transfer Time AC Mode to Batt Mode Zero Inverter to Bypass 4 ms Typical Waveform Batt Mode Pure Sinewave EFFICIENCY AC Mode 88 89 90 Batt...

Страница 22: ...Current Crest Ratio 3 1 Harmonic Distortion 3 THD linear load 6 THD non linear load Transfer Time AC Mode to Batt Mode Zero Inverter to Bypass 4 ms Typical Waveform Batt Mode Pure Sinewave EFFICIENCY...

Страница 23: ...21 Note...

Страница 24: ...22 Power Inspired Ltd Units 5 7 High Point Riding Road Buckingham Road Industrial Estate Brackley Northamptonshire NN13 7BH United Kingdom www powerinspired com...

Отзывы: