CONNECTION TO THE POWER SUPPLY

Electrical Safety

1.  Double Insulated tools are equipped with a polarized plug (one blade is wider than the other.) 

This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, 

reverse the plug. If it still does not fit, contact a qualified electrician to install a polarized 

outlet. Do not change the plug in any way. Double insulation eliminates the need for the three 

wire grounded power cord and grounded power supply system.

2.

Avoid body contact with grounded surfaces such as pipes, radiators, ranges and refrigerators. 

There is an increased risk of electrical shock if your body is grounded.

3.  Don't expose power tools to rain or wet conditions. Water entering a power tool will increase 

the risk of electrical shock.

4.  Do not abuse the cord. Never use the cord to carry the tools or pull the plug from the outlet. 

Keep cord away from heat, oil, sharp edges or moving parts. Replace damaged cords 

immediately. Damaged cords increase the risk of electrical shock.

Extension Cords

1.  Make sure your extension cord is in good condition. When using an extension cord, be sure to 

use one heavy enough to carry the current your product will draw. An undersized cord will 

cause a drop in line voltage resulting in loss of power and overheating. Table 1 shows the 

correct size to use depending on cord length and nameplate Ampere rating. If in doubt, use 

the next heavier gauge. The smaller the gauge number, the heavier the cord.

2.  When operating a power tool outside, use an outdoor extension cord marked "W-A" or "W". 

These cords are rated for outdoor use and reduce the risk of electrical shock.

3.  Use only UL listed extension cords. Inspect extension cord before use and never use damaged 

or altered extension cords. Follow extension cord manufacturer safety instruction.

4.  Keep cord away from heat, oil, sharp edges or moving parts. Replace damaged cords 

immediately. Damaged cords increase the risk of electrical shock.

Amp

Volts

25 ft.

50ft

100ft

150 ft

1-5

120V

18

16

16

14

6-10

120V

16

16

14

12

11-12

120V

14

14

14

12

12-16

120V

14

12

Not Recommended

Table 1.

Minimum Gage For Power Cord

Total Length of cord in feet

Rating

AWG

ASSEMBLY (continued)

Using the Sandpaper Punch Plate

1.

(SEE FIGURE 4)

 Align the tabs (1) on the 

punch plate with any two adjacent sides of 

the sander base (2).

2.  Press down to punch the 8 dust evacuation 

holes in the sandpaper. Remove the 

punch plate. 

NOTE:

 Punch plate may be mounted 

directly to work surface with flathead 

screws (not provided). Holding sander by 

the palm grip, push base down onto punch 

plate to perforate paper.

Installing the Dust Collector

1. 

(SEE FIGURE 5)

 Grasp the dust collector by 

the plastic housing (1) near the collar and 

insert the tube of the dust bag Into the dust 

evacuation chute (2) at the rear of the 

sander. The rubber O-ring on the tube will 

retain the bag and provide a tight seal. 

NOTE:

 The holes in the sandpaper must 

be aligned with the holes in the sander base 

for the dust collection system to work.

2.  To clean the bag, grasp it by the housing (1) 

and with a slight twisting motion remove it 

from the chute.

Figure 4

Figure 5

1

1