background image

LSB-3000 Series

jjautomation.com

Safety Instructions 1

These safety instructions are intended to prevent hazardous situations and/or equipment damage. 
These instructions indicate the level of potential hazard with the labels of 

“Caution,” “Warning” 

or 

“Danger

.

” 

They are all important notes for safety and must be followed in addition to International 

Standards (IEC)

Note 1)

, and other safety regulations. 

Note 1) IEC 60079-0 : 2007 

  EN 60079-0 : 2009 

      IEC 60079-1 : 2007 

  EN 60079-1 : 2007 

Caution 

Caution 

indicates a hazard with a low level of risk which, if not avoided, could result in 

minor or moderate injury. 

Warning 

Warning 

indicates a hazard with a medium level of risk which, if not avoided, could 

result in death or serious injury. 

Danger 

Danger 

indicates a hazard with a high level of risk which, if not avoided, will result in 

death or serious injury. 

Warning

 

1. The compatibility of the product is the responsibility of the person who designs the equipment or

decides its specifications.

Since the product specified here is used under various operating conditions, its compatibility with specific
equipment must be decided by the person who designs the equipment or decides its specifications based
on necessary analysis and test results. The expected performance and safety assurance of the equipment
will be the responsibility of the person who has determined its compatibility with the product. This person
should also continuously review all specifications of the product referring to its latest catalogue information,
with a view to giving due consideration to any possibility of equipment failure when configuring the
equipment.

2. Only personnel with appropriate training should operate machinery and equipment. The product

specified here may become unsafe if handled incorrectly.

The assembly, operation and maintenance of machines or equipment including our products must be
performed by an operator who is appropriately trained and experienced.

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.

1. The inspection and maintenance of machinery/equipment should only be performed after measures to
prevent falling or runaway of the driven objects have been confirmed.
2. When the product is to be removed, confirm that the safety measures as mentioned above are
implemented and the power from any appropriate source is cut, and read and understand the specific
product precautions of all relevant products carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and
malfunction.

4. Contact POWER-GENEX beforehand and take special consideration of safety measures if the

product is to be used in any of the following conditions.

1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to
direct sunlight.
2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping,
vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or
other applications unsuitable for the standard specifications described in the product catalogue.
3. An application which could have negative effects on people, property, or animals requiring special safety
analysis.
4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a
mechanical protective function, and periodical checks to confirm proper operation.

5. Do not open when an explosive gas and dust atmosphere may be present

6. To avoid the risks of electrostatic discharges, the user has to make sure of the absence of

dangerous atmosphere before cleaning the device, or will have to clean it only with a damp cloth or
antistatic products.

Содержание LSB-3 Series

Страница 1: ...Instruction and Operating Manual Valve Monitoring Indicator LSB 3 Series Ver 1 0 ...

Страница 2: ... of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or attempt to remove product and machinery equipment until safety is confirmed 1 The inspection and maintenance of machinery equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed 2 When th...

Страница 3: ...ty a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to using POWER GENEX products please read and understand the warranty terms and disclaimers noted in the specified catalogue for the particular products Note 2 Vacuum pads are excluded from this 1...

Страница 4: ...nside the positioner if exposed to high temperature and humidity Take enough measures against condensation especially when packing for export 4 Keep magnetic field off the positioner as this affects its characteristics Air Supply Caution 1 Use only dehumidified and dust extracted clean compressed air as the air supply 2 Do not use compressed air containing chemicals organic solvents salinity or co...

Страница 5: ...optionally SPDT DPDT P F NJ2 V3 N P F NJ2 12GM N Potentiometer for position feedback Able to Bottom visual indicator The followings are descriptions of internal parts without cover No Description 1 Main body 2 Switches or sensors 3 Terminal 4 Ground 5 Feedback shaft 6 Cam 7 Terminal bracket 8 Cable entry ...

Страница 6: ... 1 2 NPT 1 2 M20 x 1 5 PT 3 4 NPT 3 4 NPT 3 4 Body material painting Aluminum diecast powder coating Stainless steel 316SS Weight 2 Kg 4 kg See Ambient Temperature See Specifications of Switches and Sensors 4 Description on Nameplate ᆢ MODEL NUMBER Model number and options are described ᆢ Switch Type Mechanical switches Proximity sensors type Magnet sensors type GO switch type ᆢ Voltage Ratings sw...

Страница 7: ...P66 6 IP code IP67 7 IP68 8 Beacon Indicator Beacon indicator 90 open close A Bottom indicator 90 open close B Beacon Bottom indicator 90 open close C Other flow direction indicator L or T port D Electrical PF 3 4 A Connections NPT 3 4 LSB 31xx only NPT 3 4 B PF 1 2 C NPT 1 2 E M25 F Numbers of Electrical Connections 2 pcs 2 3 pcs 3 Feedback Shaft Rotary type NAMUR shaft direct mounting N Fork lev...

Страница 8: ...A 0 05A 10A 10A 10A 0 6A 0 3A 3A 6A 4A 0 1A 0 05A Wiring Operating Temperature 30 105 6 1 2 SPDT V7 1C17E9 022 Honeywell Gold SPDT Mechanical Switch Type Resistive load Inductive load Rating 125VAC 250VAC 277VAC 125VDC 250VDC 15 1A 1 2HP 15 1A 1 2HP 15 1A 1 2HP 0 5A 0 25A Wiring Operating Temperature 40 82 6 1 3 DPDT Licon 22 ITW DPDT Mechanical Switch Type Resistive load Inductive load Rating 125...

Страница 9: ... F Proximity Switch General Specifiactions Switching element function Rated operating distance Installation Output polarity Assured operating distance NAMUR NC 2mm flush Safety Function 0 1 62 mm Nomial Ratings Nominal voltage Switching frequency Hysteresis Current consumption Mesasuring plate not detected Measuring plate detected 8 VDC 0 2000 Hz 3 3mA 1mA Wiring Mechanical Specifications Connecti...

Страница 10: ...damage or malfunctions Explosion proof construction LSB 3 becomes explosion proof as certified by IECEx ATEX KC according to the model selected The explosion proof grade has the following approval Ex d IIC T Take extra care when handling the LSB 3 as explosion proof equipment To use as Ex d IIC T A Pressure proof packing As shown below in the chart use Cable gland B Metal Piping Attach the sealant...

Страница 11: ...on the terminal chamber section of the unit It is necessary to set Zero and Span of position transmitter manually The power supply of 12 30VDC should be supplied Install the LSB 7 properly before setting the position transmitter Check the proper position of the RA DA switch before setting 1 Turn the Zero screw until the output signal reaches 4mA 2 Turn the Span screw until the output signal reache...

Страница 12: ... Switches a Push up the red cam if it is necessary to set the position of the red cam b Turn the red cam until it touches the limit switch And put down and fix it with a wrench bolt c Do the same procedure for setting of the blue cam But push it down to move ...

Страница 13: ...LSB 3000 Series jjautomation com 12 10 Dimensions ...

Страница 14: ... Series jjautomation com 13 J J Automation UK Ltd Unit 5 6 Lime Tree Business Park Lime Tree Road Matlock Derbyshire DE4 3EJ U K Tel 44 1629 55577 Website jjautomationcom Subject to change without prior notice ...

Отзывы: