Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com

Installation & Operation

Electrical:

This pump will come equipped with a 6 Ft. 

long soft jacketed 3 prong electric cord and 

strain relief connection for “outlet plug in” 

installations. The pump must be within 6 foot 

of a 115 volt receptacle.

Operating voltage and other electrical 

data can be found on the nameplate. All 

models have thermal protection and require 

no additional external protection. The 

temperature of the winding will never exceed 

allowable limits, even in locked rotor.

Installation Requirements

1. Thoroughly clean and flush the system prior 

to pump installation.

2. Ensure that water does not enter the 

terminal box during the installation.

3. (Open System) Install the pump in the 

supply line; the suction side of the pump 

should be flooded with water. Ensure that the 

static head requirement from chart is achieved.

4. 

DO NOT START THE PUMP UNTIL THE 

SYSTEM HAS BEEN FILLED.

Start-Up

Do not use the pump to vent the system. Do 

not start the pump before filling the system. 

NEVER OPERATE THE PUMP DRY

.

Operation

These circulating pumps will operate quietly 

and efficiently and provide years of service if 

sized for correct performance and installed 

properly. Under 

NO

 circumstances should the 

pump be operated without water circulation 

or without the minimum required inlet 

pressure for prolonged periods of time. This 

could result in motor and pump damage.

Failure To Operate

When the pump is first started, the shaft may 

rotate slowly until water has fully penetrated 

the bearings. If the pump does not run, the 

shaft can be rotated manually. To accomplish 

this, switch off the electrical supply and close 

the isolation valves on each side of the pump. 

Remove the indicator plug in the middle of the 

nameplate. Insert a small flat blade screwdriver 

into the end of the shaft and gently turn until 

the shaft moves freely. Replace and tighten the 

plug. Open the isolation valves and wait 2 to 

3 minutes for the system pressure to equalize 

before starting the pump.

PFWRC67S1U 

 

Wet Rotor Circulator Pumps

PFRFV - Retro-Fit Valve

The thermostatic Lead-Free Bronze bypass valve is installed under the 

sink fixture furthest from the hot water heater. The valve reacts to the 

decreasing temperature in the hot water supply piping and “opens” to 

allow the flow back through the cold water piping (essentially using 

the cold water piping as the return line) and providing “instant” hot 

water at the fixtures.

NOTE: The Retro-Fit Valve (PFRFV) MUST be installed with

Power-Flo Pumps Model PFWRC67S1U circulator pump.

Содержание PFWRC67S1U

Страница 1: ...NER S MANUAL PFWRC67S1U Wet Rotor Circulator Pump For Indoor Use Only Maintenance Free Power Flo Pumps Systems Your Power Ful partner for all your pumping needs NSF NSF Certified to NSF372 E474960 877 24PUMPS www powerflopumps com ...

Страница 2: ...peration Allow time for pumps to cool before handling or servicing Features These Power Flo Circulator Pumps are designed to be installed in residential potable domestic hot water systems to provide recirculation in a RETRO FIT application where NO dedicated recirculation pipe has been installed of domestic hot water resulting in instant hot water at fixtures throughout the house This unit is desi...

Страница 3: ...w Gal C Cast Iron B Lead Free Bronze S Stainless Steel 1 115 V 2 230V 1P F Flanged S Copper Sweat U Union EXAMPLE PFWRC2120C1F Power FloPumps WetRotorCirculator 21 ShutOffHead 20GPMMaxFlow CastIronVolute 115Volt FlangedConnection MODEL PART NUMBER VOLUTE Material VOLTS PHASE AMPS WATTS SYSTEM TYPE CAPACITOR WT lbs PFWRC67S1U Stainless 115 1 0 22 25 Open 2mfd 450V 5 Wet Rotor Circulator Pumps PFWRC...

Страница 4: ...ed inlet pressure is the minimum allowable system pressure In a system open to the atmosphere the required inlet pressure is the minimum distance the pump must be located below the lowest possible water level of the water source Installation Position of terminal box Proper installation of the pump will have the terminal box located to one side of the pump with the conduit entry up See Figure 2 Thi...

Страница 5: ... 2 Hot Water To Faucet Flow Rate Adjustment Hot Water Supply Cold Water To Faucet Cold Water Supply Quick and easy under the fixture installation Furthest point from water heater Optional Snap on Aquastat PFSOA Retro Fit Valve PFRFV Optional 7 Day Digital Programmable Timer PFDT PFWRC67S1U Hot Water Heater Figure 2 Cold Water Hot Water ...

Страница 6: ...or correct performance and installed properly Under NO circumstances should the pump be operated without water circulation or without the minimum required inlet pressure for prolonged periods of time This could result in motor and pump damage Failure To Operate When the pump is first started the shaft may rotate slowly until water has fully penetrated the bearings If the pump does not run the shaf...

Страница 7: ...or up to 7 days similar to a programmable thermostat The timer is plugged into a standard wall outlet and the circulator pump is then plugged into the timer allowing for time control of the pump This unit has an internal battery backup which will in the event of loss of AC power power the unit and save maintain program settings battery will last for 48 hours before needing to be recharged NOTE The...

Страница 8: ...s including but not limited to the following sand gravel cement mud tar hydrocarbons hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive substances wash towels or feminine sanitary products etc in all pumping applications The warranty set out in the paragraph above is in lieu of all other warranties expressed or implied and we do not authorize any representative or oth...

Отзывы: