background image

Power-Flo Pumps & Systems • 877-24PUMPS • www.powerfl opumps.com

4

Specifi cations

PF30A          

 

 

 

 

Portable 

Utility 

Pumps

Dimensions

DISCHARGE

1¼” NPT Male, Vertical

LIQUID 
TEMPERATURE

77°F Continuous

MOTOR HOUSING

Thermoplastic

PUMP STRAINER

Thermoplastic

IMPELLER

Semi-open
Material: Thermoplastic

SHAFT

Steel

O-RINGS

Buna-N

HARDWARE

Stainless Steel

SEAL

Single Mechanical, Type 6
Material: Carbon/Ceramic/Buna-N

UPPER BEARING

Single, Row, Ball, Oil Lubricated

LOWER BEARING

Single, Row, Ball, Oil Lubricated

POWER CORD

10 Ft., cord with plug

MOTOR

Air Filled, Class B insulation

SINGLE PHASE

Permanent Split Capacitor (PSC). Includes 
Thermal Overload Protection in Motor

LEVEL CONTROL

Integral with pump

IMPORTANT! - For use in pumping water only!

Series:  

PF30A

 

       

1/3HP, 3450 RPM, 60 Hz

Portable Sump/Utility Pumps

MODEL

HP

Hz

Volts/Ph

RPM

Full Load Amps

Cord Length Cord Type

PF30A

1/3

60

115/1

3450

2.6

10 Ft.

SJTW

Locked Rotor Amps

NEMA Start Code

Winding Resistance, MAIN-START

10.3

B

2.9 -- 28.8

®

BACK TO INDEX

Содержание PFUT06 Series

Страница 1: ...MPS www powerflopumps com ISP No PF30_PFUT06 4 10 INSTALLATION SERVICE PARTS MANUAL Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Series PFUT06 PF30A 1 6 HP 1 3HP 3450 RPM 60 Hz Portable U...

Страница 2: ...e protection when working on pumps DO NOT use power cord to lift pump Protect cable from cuts and punctures Do not handle power cable with wet hands DO NOT us these pumps in water over 77 F Pumps buil...

Страница 3: ...NG Single Row Ball Oil Lubricated LOWER BEARING Single Row Ball Oil Lubricated POWER CORD 15 Ft cord with plug MOTOR Air Filled Class B insulation SINGLE PHASE Permanent Split Capacitor PSC Includes T...

Страница 4: ...Buna N UPPER BEARING Single Row Ball Oil Lubricated LOWER BEARING Single Row Ball Oil Lubricated POWER CORD 10 Ft cord with plug MOTOR Air Filled Class B insulation SINGLE PHASE Permanent Split Capaci...

Страница 5: ...Power Flo Pumps Systems 877 24PUMPS www powerflopumps com 5 PFUT06 PF30A Portable Utility Pumps Performance BACK TO INDEX...

Страница 6: ...cord directly into GFI outlet Level Control Basic Instructions Plug the level control plug into the GFI receptacle then plug the pump into the piggy back plug See Figure 2 One cycle of operation shou...

Страница 7: ...plugging screen and suction intake 1 Check all electrical connections for security Have electrician measure current in motor leads if current is within 20 of locked rotor Amps impeller is probably lo...

Страница 8: ...ined in accordance with Manufacturer s installation instructions that has been exposed to outside substances including but not limited to the following sand gravel cement mud tar hydrocarbons hydrocar...

Отзывы: