PF5CU, PF7CU   

 

 

 

 

               Self-Priming Universal Pumps

General Safety Information

® Power-Flo  is a registered trademark of Power-Flo Technologies Inc.

Other brand and product names are trademarks or registered trademarks of their respective holders.

Alteration Rights Reserved.  7/08, 7/09, 3/10, 2/11, 4/12, 1/13, 5/13, 8/14, 12/19, 9/2020, 1/2021

Before installation, read the following 
instructions carefully. Failure to follow 
instruction and Safety information could 
cause serious bodily injury, death and/or 
property damage. Each Power-Flo pump is 
individually factory tested to insure proper 
performance. Closely following these 
instructions will eliminate potential operating 
problems, assuring years of trouble-free 
service.

                                           “

Danger” indicates

 

 

        an imminenty 

hazardous situation which, if not avoided, 

WILL result in death or serious injury.

                                                 “Warning” indicates

 

 

        an imminenty 

hazardous situation which, if not avoided, 

MAY result in death or serious injury.

 

 

        “Caution”  indicates

 

 

         an potentially 

hazardous situation which, if not avoided, 

MAY result in minor or moderate injury.

IMPORTANT - Power-Flo Pumps and 

Systems is not responsible for losses, injury 

or death resulting from failure to observe 

these safety precautions, misuse, abuse or 

misapplication of pumps or equipment.

 ALL

 

RETURNED 

 PRODUCTS MUST BE
 CLEANED, SANITIZED,
 OR DECONTAMINATED
 PRIOR TO SHIPMENT, TO 

INSURE EMPLOYEES WILL NOT BE EXPOSED 
TO HEALTH HAZARDS IN HANDLING SAID 
MATERIAL. ALL APPLICABLE LAWS AND 
REGULATIONS SHALL APPLY.

 

 

       Installation, wiring,

 

 

       and junction 

connections must be in accordance with 
the National Electric Code and all applicable 
state and local codes. Requirements may 
vary depending on usage and location.

 

 

        Installation and

 

 

        servicing is to be 

conducted by qualified personnel only.

  

 

        Keep clear of suction

 

 

       and discharge

 openings. 

Do not

 insert fingers in 

 pump with power connected.

 

 

       Always wear eye

 

 

       protection when 

working on pumps. Do not wear loose 
clothing that may become entangled in 
moving parts

 

  

      Pumps build up heat 

  and pressure during
 operation. Allow time
 for pumps to cool 
 before handling or
 servicing.  

 

 

      This pump is 

not

   

      intended for use

 in swimming pools or water 
 installations where human 
 contact with pumped fluid. 

 

 

       Risk of electric shock. 

 

 

       To reduce risk of 

  electric shock, always disconnect 
  pump from power source before 
  handling. 

Lock out power & tag.

 

 

       

Do not

 us these 

 

 

       pumps in water 

over 160˚F. 

Do not

 exceed manufactures 

recommended maximum performance, as 
this could cause the motor to overheat.

 

 

      Operation against a

  closed discharge
  valve will cause
  premature bearing
  and seal failure. 
 Heat build up on 

self-priming and end suction pumps 
may cause dangerous pressures. A high 
temperature switch or pressure relief valve 
is recommended to be be installed in pump 
case.

 

 

      Carefully read 

 

 

      instruction manuals 

supplied with motor or engine before 
operating or servicing.

 

 

      DO NOT

 pump 

   

      hazardous material. 

  These pumps are NOT to be
  installed in locations classified as
  hazardous in accordance with the

National Electric Code, ANSI/NFPA 70.

      
 

 

      

Pumps constructed

  

      with or fitted with

 bronze/brass may contain lead

 levels higher than considered 

 safe for potable water systems. 

Lead is known to cause cancer and birth 

defects or other reproductive harm. 

Various government agencies have 

determined that leaded copper alloys 

should not be used in potable water 

applications.

IMPORTANT!

Prior to installation, record Model 

Number, MFG Date, and/or serial number, 

from pump name plate for future 

reference. 

Model:
Serial:
MFG Date:

WARNING: 

CANCER AND REPRODUCTIVE HARM-

WWW.P65WARNINGS.CA.GOV

Содержание PF5CU

Страница 1: ...877 24PUMPS www powerflopumps com ISP No PF5_7CU 1 2021 INSTALLATION SERVICE PARTS MANUAL Series PF5CU 1 1 2 x 1 1 2 PF7CU 2 x 2 Universal Drive Frame Mtd...

Страница 2: ...nding on usage and location Installation and servicing is to be conducted by qualified personnel only Keep clear of suction and discharge openings Do not insert fingers in pump with power connected Al...

Страница 3: ...LER Open trash type dynamically balanced Material Cast Iron Class 30 O RINGS Buna N HARDWARE Steel Stainless Steel PAINT Air dry enamel SEAL Mechanical Self lubricating Material Graphite Ceramic NBR 3...

Страница 4: ...1 2 NPT 1 1 2 NPT Not for pumping flammable liquids or hazardous materials that is not compatible with pump materials Model Weight Suction Discharge PF7CU 82 lbs 2 NPT 2 NPT Not for pumping flammable...

Страница 5: ...5 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Performance PF5CU Self Priming Universal Pumps...

Страница 6: ...6 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Performance PF7CU Self Priming Universal Pumps...

Страница 7: ...ould not be operated without a suction strainer to prevent foreign matter from being drawn into impeller The strainer should be cleaned regularly The use of pipe the same size as the port size is high...

Страница 8: ...es To reassemble lightly oil ring and press stationary member over shaft and into pedestal 6 Lightly oil shaft 23 and inner surface of bellows of rotating member With lapped surface facing pedestal sl...

Страница 9: ...24PUMPS www powerflopumps com Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List Figure 1 PF5CU 7CU...

Страница 10: ...ber 88 x 70 x 3mm PF017714 PF017714 15 1 Pipe plug 1 75 NPT 16 1 Body Cast iron PFCI5CCETNK PF23723 Check Valve Assy Includes items 17 18 19 20 21 22 PF017718 PF017718 2 17 1 Weight 2 50 O D Steel PF0...

Страница 11: ...me pump body before restarting 3 Lower suction head install foot valve and prime 4 Increase inlet pressure by adding more water to tank or increasing back pressure by turning gate valve on discharge l...

Страница 12: ...ed operated or maintained in accordance with Manufacturer s installation instructions that has been exposed to outside substances including but not limited to the following sand gravel cement mud tar...

Отзывы: