Risk of electric shock. Always disconnect the pump from the power source before handling inspections or repairs.

Symptom

Possible Cause(s)

Corrective Action

Little or no discharge and will not prime

1. Pump body not filled with water

2. Total head too high

3. Suction head higher than pump designed for

4. Impeller partially or completely plugged

5. Leak in suction line

6. Foot-valve too small

7. Impeller damaged

8. Foot-valve or suction line not submerged deep

    enough in water, pulling air

9. Insufficient inlet pressure or suction head

10. Suction piping too small

11. Body gasket leaking

12. Suction or discharge line valves closed

13. Piping damaged

14. Clogged strainer or foot-valve

1. Fill pump body with water.

2. Shorten suction head

3. Lower suction head, install foot-valve and prime

4. Disassemble pump and clean out impeller

5. Repair or replace suction line

6. Match foot-valve size to piping or install one 

    larger size foot-valve

7. Disassemble pump and replace impeller

8. Submerge lower in water

9. Increase inlet pressure by adding more water to

    tank or increasing back pressure by turning gate 

    valve on discharge line partially closed.

10. Increase pipe size to pump inlet size or larger

11. Replace

12. Open

13. Clean or replace

14. Clean or replace

Loss of suction after satisfactory operation

1. Air leak in suction line

2. When pump was last turned off, water siphoned

    out of pump body

3. Suction head higher than pump designed for

4. Insufficient inlet pressure or suction head

5. Clogged foot-valve, strainer or pump

6. Defective wearplate

1. Repair or replace suction line

2. Refill (re-prime) pump body before restarting

3. Lower suction head, install foot-valve and prime

4. Increase inlet pressure by adding more water to

    tank or increasing back pressure by turning gate 

    valve on discharge line to partially closed.

5. Unclog or replace

6. Replace

Pump overloads driver

1. Total head lower than pump rating, unit 

    delivering too much water

2. Specific gravity and viscosity of liquid being 

    pumped different than the pump rating

1. Increase back pressure by turning gate 

    valve on discharge line to partially closed

    position that will not overload motor.

2. Consult factory

Pump vibrates and/or makes excessive noise

1. Mounting plate or foundation not rigid enough

2. Foreign material in pump causing unbalance

3. Impeller bent

4. Cavitation present

5. Piping not supported to relieve any strain on

    pump assembly

1. Reinforce

2. Disassemble pump and remove

3. Replace impeller

4. Check suction line for proper size and check

    valve in suction line if completly open, remove 

    any sharp bends before pump and shorten 

    suction line

5. Make necessary adjustments

Pump runs but no fluid

1. Air leak in suction piping

2. Pump located too far from fluid source

3. Gate valve closed

4. Clogged strainer

5. Fouled foot-valve

6. Discharge height too great

7. Fouled impeller

8. Faulty mechanical seal

1. Replace

2. Replace

3. Open

4. Clean or Replace

5. Clean or Replace

6. Lower the height

7. Clean or Replace

8. Replace

Pump leaks at shaft

1. Worn mechanical seal

2. Seal not installed properly

1. Replace

2. Follow  service instructions for installing seal

NOTE: 

 Power-Flo Pumps & Systems assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied 

accessories other than at Power-Flo Pumps & Systems or its authorized service centers, automatically voids warranty.

Trouble Shooting Chart

PF5CU, 7CU 

 

 

 

 

 

               Self-Priming Universal Pumps

Содержание PF5CU

Страница 1: ...877 24PUMPS www powerflopumps com ISP No PF5_7CU 1 2021 INSTALLATION SERVICE PARTS MANUAL Series PF5CU 1 1 2 x 1 1 2 PF7CU 2 x 2 Universal Drive Frame Mtd...

Страница 2: ...nding on usage and location Installation and servicing is to be conducted by qualified personnel only Keep clear of suction and discharge openings Do not insert fingers in pump with power connected Al...

Страница 3: ...LER Open trash type dynamically balanced Material Cast Iron Class 30 O RINGS Buna N HARDWARE Steel Stainless Steel PAINT Air dry enamel SEAL Mechanical Self lubricating Material Graphite Ceramic NBR 3...

Страница 4: ...1 2 NPT 1 1 2 NPT Not for pumping flammable liquids or hazardous materials that is not compatible with pump materials Model Weight Suction Discharge PF7CU 82 lbs 2 NPT 2 NPT Not for pumping flammable...

Страница 5: ...5 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Performance PF5CU Self Priming Universal Pumps...

Страница 6: ...6 Power Flo Pumps Systems 877 24PUMPS www powerflopumps com Performance PF7CU Self Priming Universal Pumps...

Страница 7: ...ould not be operated without a suction strainer to prevent foreign matter from being drawn into impeller The strainer should be cleaned regularly The use of pipe the same size as the port size is high...

Страница 8: ...es To reassemble lightly oil ring and press stationary member over shaft and into pedestal 6 Lightly oil shaft 23 and inner surface of bellows of rotating member With lapped surface facing pedestal sl...

Страница 9: ...24PUMPS www powerflopumps com Repair Parts For Repair Part Please supply Model Number and MFG Date as shown on Name Plate and Part Description and Part Number as shown on Parts List Figure 1 PF5CU 7CU...

Страница 10: ...ber 88 x 70 x 3mm PF017714 PF017714 15 1 Pipe plug 1 75 NPT 16 1 Body Cast iron PFCI5CCETNK PF23723 Check Valve Assy Includes items 17 18 19 20 21 22 PF017718 PF017718 2 17 1 Weight 2 50 O D Steel PF0...

Страница 11: ...me pump body before restarting 3 Lower suction head install foot valve and prime 4 Increase inlet pressure by adding more water to tank or increasing back pressure by turning gate valve on discharge l...

Страница 12: ...ed operated or maintained in accordance with Manufacturer s installation instructions that has been exposed to outside substances including but not limited to the following sand gravel cement mud tar...

Отзывы: