3/8 in. Right Angle Air Drill
11
Visit www.princessauto.com for more information
8011796
V 2.7
TROUBLESHOOTING
If the tool does not function properly or if it is missing parts, contact Princess Auto Ltd. for a solution. If
unable to do so, have a qualified technician service the tool.
Problem(s)
Possible cause(s)
Suggested solution(s)
Tool runs at normal speed but
loses power under load.
Motor parts worn.
Have a qualified technician
replace worn parts.
Lack of air tool oil.
Pour air tool oil into air inlet
per instructions.
Tool runs slowly. Air flows
slightly from exhaust.
Motor parts jammed with
dirt particles.
OR
Air flow blocked by dirt.
1. Check air inlet filter
for blockage.
2. Pour air tool oil into air inlet
as per instructions.
3. Operate tool in short bursts.
4. Disconnect air supply.
Free motor by rotating
drive shank manually
where applicable.
5. Repeat above as needed.
If this fails, bring to
Princess Auto Ltd. or to a
qualified technician.
Excessive air tool oil in tool.
Run tool under no load for
short periods of time until
exhaust clears.
Buildup of shipping grease.
See Removing Packing
Grease section.
Air Flow Regulator is in the
closed position
Open regulator to
correct position