Maintenance

Battery replacement
1. Power is supplied by a 9 volt cell

battery.

2. Remove the battery cover by

gently sliding it toward the bottom
of the meter.

3. Remove and disconnect the old

battery from the meter and replace
with a new unit. Wind the excess
lead length and put the top of the
battery beneath the the battery
chamber. Install the battery and
replace the battery cover.

Cleaning
Periodically wipe the case with a damp cloth and detergent, do not use
abrasives or solvents.

Substance
Asphalt
Concrete
Cement
Sand
Earth 
Water
Ice
Snow
Glass
Ceramic
Marble
Plaster
Mortar
Brick (red)
Cloth (black)
Human skin
Lather
Charcoal (powder)
Lacquer
Lacquer (matte)
Rubber (black)
Plastic
Timber
Paper
Chromium oxides
Copper oxides
Iron oxides
Textiles

Thermal emissivity
0.90 to 0.98
0.94
0.96
0.90
0.92 to 0.96
0.92 to 0.96
0.96 to 0.98
0.83
0.90 to 0.95
0.90 to 0.94
0.94
0.80 to 0.90
0.89 to 0.91
0.93 to 0.96
0.98
0.98
0.75 to 0.80
0.96
0.80 to 0.95
0.97
0.94
0.85 to 0.95
0.90
0.70 to 0.94
0.81
0.78
0.78 to 0.82
0.90

Avoid exposure: 
Laser radiation is emitted from the
aperture

Caution
Laser radiation - do not stare into beam
Power Out: <1mW
Wave length: Red (630 to 670 nm)
Laser safety classification: Class II

Содержание 8001782

Страница 1: ...Digital Infrared Thermometer 8 80 00 01 17 78 82 2 Owner s Manual ...

Страница 2: ...N Do not use the unit near any device that generates strong electromagnetic radiation or near a static electrical charge as these may cause inaccurate readings Do not use the unit where it may be exposed to corrosive or explosive gasses The unit could be damaged or explosion may occur Do not keep or use this unit in an environment where it will be directly illuminated by sunshine or where it will ...

Страница 3: ...t rate 0 25 second nominal Operating environment 32 F to 122 F 0 C to 50 C at 70 relative humidity Storage temperature 4 F to 140 F 20 C to 60 C Auto power off 10 seconds Standby consuming current 5µA Battery Standard 9V battery Average battery life 9 hours Dimensions 6 x 4 x 1 1 2 150 mm x 150 mm x 42 mm Laser Specifications Laser safety classification of class 2 Wave length Red 630 670nm Operati...

Страница 4: ...off the battery cap and then slide the switch to select C or F Operation 1 Take the protective cap off and then pull the trigger to turn on the meter 2 Point the lens at the object whose temperature is to be measured 3 Referring to the spot size figure below aim the laser beam at the object whose temperature is to be measured 4 Pull the trigger Measurement is performed as long as trigger is held 5...

Страница 5: ...nfrared radiation and a 5 3 µm cut off filter The output signal from the infrared radiation sensor is input to an electronic circuit along with the output signal from a standard temperature thermopile Emissivity All objects emit infrared energy The amount of energy emitted is proportional to the object s temperature and its ability to emit INFRA RED energy This ability called emissivity is based u...

Страница 6: ... Concrete Cement Sand Earth Water Ice Snow Glass Ceramic Marble Plaster Mortar Brick red Cloth black Human skin Lather Charcoal powder Lacquer Lacquer matte Rubber black Plastic Timber Paper Chromium oxides Copper oxides Iron oxides Textiles Thermal emissivity 0 90 to 0 98 0 94 0 96 0 90 0 92 to 0 96 0 92 to 0 96 0 96 to 0 98 0 83 0 90 to 0 95 0 90 to 0 94 0 94 0 80 to 0 90 0 89 to 0 91 0 93 to 0 ...

Отзывы: