- 31 -
1901-EN Wartung_2858
maInTenance
EN
NOTE
Property damage caused by the dowel pins becoming
loose
•
After any repair or maintenance work on the
rotary unit, check the position of the dowel
pins (see detail B)
•
Check the position of the dowel pins at least
once a year (see detail B)
B
Changing the bearing bush of the tine arms
NOTE
Property damage caused by the shaft W becoming
loose and distance A too great
•
Check the distance A at least once a year.
•
The distance (A) should be approx. 1 mm in
normal operation. If the shaft (W) play is
greater, then it can be corrected with shims.
•
If the distance (A) is greater than 4 mm,
then change the bushes (B) on the inside of
the tine arms.