To Service the Boiler & Component Replacement - Page 27
4.3.4 Burner
Gain General Access - See 4.1
1.
Disconnect the electrode lead and earth wire.
2.
Undo the fixing screw, hold the burner at the right
hand side and pull forwards to disconnect from the
air box.
3.
Unscrew the electrode and transfer to the new
burner.
4.
Re-assemble in reverse order, on re-assembly
hook the rear of the locating bracket (1) in place
before locating the front (2).
4.3.5 Injector
Gain General Access - See 4.1
1.
Remove the burner - See 4.3.4.
2.
Use a 13mm (A/F) or ½" (A/F) socket spanner to
remove the injector.
3. Unscrew the injector, use a new sealing washer on
re-assembly.
If using a flat spanner to remove the injector
See the next section (4.3.6.)
4.3.6 Combustion Chamber Insulation
Gain General Access - See 4.1
1.
The front insulation is accessible as the front is
already off.
2.
Remove the burner - See 4.3.4.
3.
Remove the two screws securing the side and rear
insulation assembly to the front of the chassis.
4.
Pull the assembly forwards and away from the
boiler. Replace insulation pieces as required,
replace any securing clip if damaged.
5.
Re-assemble in reverse order.
Содержание Suprima 30
Страница 6: ...Installation Requirements Page 6 ...
Страница 10: ...Installation Requirements Page 10 Fig 3 Fig 4 ...
Страница 12: ...Flue Kits Page 12 ...
Страница 13: ...Optional Extras Flues Page 13 Installation instructions included as necessary with each kit ...
Страница 14: ...System and Other Kits Page 14 ...
Страница 15: ...System and other Kits Page 15 ...
Страница 33: ...6 Wiring Diagram Page 33 ...
Страница 36: ...8 Short List of Spare Parts Page 36 ...