Users Instructions

Programmers

Statesman 45/50, 50/70, 70/90, 90/110

The operation is shown in the instructions supplied
with the programmer kit.

Important: Where this programmer is fitted to existing
gravity systems without independent temperature
control of the domestic hot water (i.e. cylinder
thermostat/zone valve), it will not be possible to use
all the available programme options (i.e. central heating
cannot be operated separately from hot water).

Statesman Utility 

50/70, 70/90. 90/110, 110/30, 130/150

This model cannot be fitted with the optional Potterton
integral programmer. If fitting an external programmer,
the instructions on how to operate it should have been
supplied by the manufacturer.

To Turn Off the Boiler

For Long Periods

Switch off the electricity supply to the boiler.
Close all stop valves in the fuel supply pipe.
Clean flue and chimney.
Clean boiler internal surfaces.
For the winter period, drain entire system including
the domestic water supply.

To relight, refill system if previously drained and restore
controls to the original settings.

For Short Periods

Disconnect the electricity supply, and shut off the oil
supply at the storage tank.

To relight, restore the oil supply, and then the electricity
supply, reset the controls and timer, if fitted.

Clearances

The boiler must have the following minimum clearances
for servicing.

Front of Boiler

610mm

(24in)

Sides of Boiler
Balanced Flue

6mm

(1/4in)

Conventional Flue

25mm

(1in)

Top of boiler

12mm

(1/2in)

Frost Protection

If frost is likely during a short absence from home,
leave the heating controls on a time reduced setting.
Alternatively a frost stat may be fitted.

Consult your installer on whether any other thermostat
is required.

For longer periods, the entire system should be
drained, including the domestic water supply.

Frost Precaution

A boiler which is shut down for several hours in very
cold weather may be in danger of freezing due to its
position (i.e. it may be in the outhouse, etc.) or part of
the pipework of the system may be vulnerable to frost.

To avoid freezing, protection should be provided by
adequate insulation, taking care not to impede the fresh
air supply to the boiler.

Cleaning the Outside of the Casings

The outside of the boiler casing can be wiped when
necessary by using a damp clean cloth to remove
finger marks etc. Do not use abrasive cleaners as this
may damage the casing finish.

Fig. 4

ST00224A

Содержание Statesman 45/50L

Страница 1: ...ith Kerosine and for use in GB IE This boiler can be converted for use with Gas Oil CF only not 45 50L About Safety Installation must have been in accordance with the Installation Service Instructions and the rules in force Leave these instructions with the user for use on future calls Statesman 45 50L 50 70L 70 90L 90 110L Utility 50 70L 70 90L 90 110L 110 130L 130 150L Users Instructions ...

Страница 2: ...ers or spillages Fuels remove natural oils and fats and may thus cause cracking and irritation of the skin Gas oil may also cause irreversible damage to your health on prolonged or repeated skin contact Precautions ALWAYS HANDLE fuels in the open air or in a well ventilated place well away from all sources of ignition such as fires sparks hot surfaces and DO NOT SMOKE ALWAYS DRAIN fuels using a pr...

Страница 3: ... the oil to fall to the bottom of the tank as sludge might be sucked into the fuel pipe If possible switch off the burner before any fresh supply of oil is delivered and start it again about one hour later to give any dirt in the tank a chance to settle Air Supply Your installer will have made arrangements for an adequate supply of fresh air to the boiler to ensure safe operation Do not block any ...

Страница 4: ... 180 F For milder or summer conditions it may be advisable to set the knob on or about the seventh dot from minimum Never leave the boiler thermostat at a setting between OFF and the minimum setting otherwise serious corrosion of the boiler will occur See Fig 3 Boiler Thermostat Utility The Thermostat OFF position is designated the knob must be turned clockwise to the minimum setting 1 at this pos...

Страница 5: ...Part No 5105705 5 Users Instructions Fig 3 ST00268A Optional Programmer Fig 2 ...

Страница 6: ...ect the electricity supply and shut off the oil supply at the storage tank To relight restore the oil supply and then the electricity supply reset the controls and timer if fitted Clearances The boiler must have the following minimum clearances for servicing Front of Boiler 610mm 24in Sides of Boiler Balanced Flue 6mm 1 4in Conventional Flue 25mm 1in Top of boiler 12mm 1 2in Frost Protection If fr...

Страница 7: ...ring defect on the appliance only not the system or ancillary controls free of charge for parts and labour subject to there being no misuse or abuse Service visits by Potterton Service Operations outside the terms of the boiler guarantee will be charged for both parts and labour at normal rates for chargeable work During the period of the boiler guarantee Potterton will only be responsible for the...

Страница 8: ...anges and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold subject to our standard Conditions of Sale which are available on request To aid continuous improvement and staff training calls to this line may be monitored or recorded General Enquiries Tel Technical Tel Service Tel Fax Literature Request Tel Publication No 510570...

Отзывы: