Potterton Statesman 45/50L Скачать руководство пользователя страница 4

4

Part No. 5105705

Users Instructions

Failure to Light

If the boiler fails to light when required:
a)

WAIT  FOR  THREE MINUTES to allow unburnt vapour to clear from the boiler.

b) Check that the boiler thermostat, selector switch, timer or external timer, and room thermostat (where

these are fitted) are all set to call for heat.

c) Check that there is oil in the tank, and all stop valves in the oil supply pipe are open.

d) Check that the mains electricity switch is on, and that the fuse has not blown.

e) Remove the front casing by pulling forward off the mounting clips, press the reset button which will be

illuminated on the burner cover.

If the boiler still does not light, turn off the electricity supply, and contact your installer.

Boiler Controls

Boiler Thermostat - Kitchen

The Thermostat OFF position is designated, the knob must be turned to the minimum setting indicated by the first
and smallest 'dot', at this position the hot water from the boiler will be at approximately 55°C (130°F).

At the maximum setting, i.e., the last and largest 'dot' on the panel, the temperature of the outlet water will be
approximately 82°C (180°F).

For milder or summer conditions it may be advisable to set the knob on or about the seventh 'dot' from minimum.

Never leave the boiler thermostat at a setting between “OFF” and the minimum setting, otherwise serious corrosion
of the boiler will occur. See Fig. 3.

Boiler Thermostat - Utility

The Thermostat OFF position is designated, the knob must be turned clockwise to the minimum setting '1', at this
position the hot water from the boiler will be at approximately 60 °C (140 °F).

At the maximum setting '5', the temperature of the outlet water will be approximately 82°C (180°F).

For milder or summer conditions it may be advisable to set the knob on setting '3'.
Never leave the boiler thermostat at a setting between “OFF” and setting '1', otherwise serious corrosion of the
boiler will occur. See Fig. 2.

Note: For a gravity feed hot water system, the boiler thermostat setting should be reduced in summer to prevent
overheating of the hot water.

Limit Thermostat

The Limit Thermostat operates if the boiler overheats for any reason. This is shown by the overheat light being lit
(not Utility models). Should this happen at any time, remove the front casing by pulling forward off the mounting
clips and press the overheat reset button (See Fig. 1). If the problem occurs again, turn off the electricity supply
and contact your installer.

Содержание Statesman 45/50L

Страница 1: ...ith Kerosine and for use in GB IE This boiler can be converted for use with Gas Oil CF only not 45 50L About Safety Installation must have been in accordance with the Installation Service Instructions and the rules in force Leave these instructions with the user for use on future calls Statesman 45 50L 50 70L 70 90L 90 110L Utility 50 70L 70 90L 90 110L 110 130L 130 150L Users Instructions ...

Страница 2: ...ers or spillages Fuels remove natural oils and fats and may thus cause cracking and irritation of the skin Gas oil may also cause irreversible damage to your health on prolonged or repeated skin contact Precautions ALWAYS HANDLE fuels in the open air or in a well ventilated place well away from all sources of ignition such as fires sparks hot surfaces and DO NOT SMOKE ALWAYS DRAIN fuels using a pr...

Страница 3: ... the oil to fall to the bottom of the tank as sludge might be sucked into the fuel pipe If possible switch off the burner before any fresh supply of oil is delivered and start it again about one hour later to give any dirt in the tank a chance to settle Air Supply Your installer will have made arrangements for an adequate supply of fresh air to the boiler to ensure safe operation Do not block any ...

Страница 4: ... 180 F For milder or summer conditions it may be advisable to set the knob on or about the seventh dot from minimum Never leave the boiler thermostat at a setting between OFF and the minimum setting otherwise serious corrosion of the boiler will occur See Fig 3 Boiler Thermostat Utility The Thermostat OFF position is designated the knob must be turned clockwise to the minimum setting 1 at this pos...

Страница 5: ...Part No 5105705 5 Users Instructions Fig 3 ST00268A Optional Programmer Fig 2 ...

Страница 6: ...ect the electricity supply and shut off the oil supply at the storage tank To relight restore the oil supply and then the electricity supply reset the controls and timer if fitted Clearances The boiler must have the following minimum clearances for servicing Front of Boiler 610mm 24in Sides of Boiler Balanced Flue 6mm 1 4in Conventional Flue 25mm 1in Top of boiler 12mm 1 2in Frost Protection If fr...

Страница 7: ...ring defect on the appliance only not the system or ancillary controls free of charge for parts and labour subject to there being no misuse or abuse Service visits by Potterton Service Operations outside the terms of the boiler guarantee will be charged for both parts and labour at normal rates for chargeable work During the period of the boiler guarantee Potterton will only be responsible for the...

Страница 8: ...anges and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold subject to our standard Conditions of Sale which are available on request To aid continuous improvement and staff training calls to this line may be monitored or recorded General Enquiries Tel Technical Tel Service Tel Fax Literature Request Tel Publication No 510570...

Отзывы: