43
14.0 Changing Components
© Baxi Heating UK Ltd 2014
14.8
Flue/Heat Exchanger Thermostat Sensor
(Fig. 72)
1. Ease the retaining tab on the sensor away and disconnect
the electrical plug.
2. Turn the sensor 90
o
anticlockwise to remove - it is a
bayonet connection.
3. Reassemble in reverse order.
14.9
Water Pressure Sensor (Fig. 74)
1. Drain the primary circuit.
2. Disconnect the two wires from the sensor.
3. Undo the nut on the flow pipe securing and sealing the
sensor.
4. Remove the sensor, examine the sealing washer, replacing if
necessary.
5. Reassemble in reverse order. The component is not
polarised - either wire will fit each terminal.
14.10
Central Heating Temperature Sensor (NTC)
(Fig. 73)
1. Ease the retaining tab on the sensor away and disconnect
the electrical plug.
2. Unscrew the sensor from it’s pocket and reassemble in
reverse order. The plug will only fit one way.
14.11
Safety Thermostat
(Fig. 73)
1. Pull the plug off the thermostat.
2. Remove the screws securing the thermostat to the
mounting plate on the flow pipe.
3. Reassemble in reverse order, ensuring that the plug is
pushed fully on.
14.12
Return Heating Temperature Sensor
(Fig. 75)
1. Ease the retaining tab on the sensor away and disconnect
the electrical plug.
2. Prise the sensor retaining clip off the pipe and remove the
sensor from the clip.
3. Reassemble in reverse order.
Central Heating
Temperature Sensor
Safety Thermostat
Flow Pipe
Fig. 73
Flue/Heat Exchanger
Thermostat Sensor
Electrical
Plug
Fig. 72
Fig. 75
Return Heating
Temperature Sensor
Fig. 74
Pressure Sensor