![Potterton Promax HE Store Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/potterton/promax-he-store/promax-he-store_installation-and-servicing-instructions-manual_1583130005.webp)
5
Panel Removal
MAX0006B
Bottom Section
Union Nuts
(remain with
Bottom Section)
DHW Sensor Pocket
(310mm deep)
Top & Bottom Section
Handholds
(Underneath boiler)
Lifting and
plumbing
access
each side
Mains power
supply and
Immersion Heater
cable entry holes
Pull up and away Top Panel
2
4
3
Pull forward Front Panel at the bottom and lift off
General Access
Plumbing Access
1
Pull forward Bottom Panel
Unscrew Upper Panel at the bottom and pull away
Retaining Screws (Upper Panel)
Condensate
outlet hole
Top Section
Lift Heat Engine onto
Cylinder. Ensure the
rollers engage into
location channels.
Tilt and slide until front
location pegs drop into
position on the cylinder.
Location Peg
Location Channel
Rollers
Fig. 1
Important:
Refer to Page 8 for Storage, Unpacking and Handling Instructions.