7.0 Emergency

11

© Baxi Heating UK Ltd 2009

If you smell gas

Turn off the gas supply at the meter and call your gas
supplier immediately.

Ventilate the property.

In GB, Transco operate a 24 hour emergency service and
the telephone number will be listed in your telephone
directory.

Faulty boiler

If it is known or suspected that a fault exists 
on the boiler, it must not be used until the fault 
has been corrected by a competent person.

Warning !

Содержание Promax 15/2 HE Plus

Страница 1: ...er Guide and Important Warranty Information Please keep these instructions in a safe place If you move house please hand them over to the next occupier Promax 15 2 24 2 30 HE Plus Condensing Central Heating Boiler You can rely on ...

Страница 2: ...K Ltd The Wyvern Business Park Stanier Way Derby DE21 6BF Full acknowledgement of author and source must be given WARNING Any person who does any unauthorised act in relation to a copyright work may be liable to criminal prosecution and civil claims for damages 1 0 Operating the Boiler 3 2 0 Troubleshooting 4 3 0 Clearances 6 4 0 Care of the Boiler 7 5 0 Legislation 8 6 0 Notes 9 7 0 Emergency 11 ...

Страница 3: ...t harmful to the individual or the working of the boiler in any way Other Controls A Potterton Electronic Programmer or other type of clock should have been fitted in your system together with heating and hot water controls Full instructions on the use of these controls will have been supplied with them 1 2 To Light 1 Ensure that the main gas and electricity supplies to the boiler are ON 2 The fan...

Страница 4: ... supplier Is there electricity to the boiler Check electrical supply to boiler is switched on NO YES Ignition Spark will commence Boiler operating satisfactorily NO YES YES YES Boiler fails to light YES Press the Reset Button If boiler will not light CONTACTYOUR INSTALLER OR SERVICE ENGINEER Boiler flame established Check that a flame is visible through the sight glass Sight Glass YES Reset Button...

Страница 5: ...ples of external timer Ensure timer is set for Central Heating ON see any instructions supplied with timer NO YES YES NO 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the system and controls contact your installer as soon as possible CH ON CH OFF ...

Страница 6: ...our boiler 6 Your boiler should have the following minimum clearances for Safety and Maintenance Figs 1 2 Top 200mm Bottom 50mm Left side 5mm Right Side 5mm Front 5mm In Operation 500mm For Servicing 7 If your boiler is installed in a compartment do not use it for storage purposes Do not obstruct any purpose provided ventilation openings 8 Flammable materials must not be stored in close proximity ...

Страница 7: ...nd then dried completely DO NOT USE ABRASIVE CLEANING AGENTS 4 2 Frost Protection 1 The boiler does not have integral frost protection It is recommended that the installer fits a suitable protection device to the system controls if required For frost protection the boiler must not be switched off at the isolation switch on the wall ...

Страница 8: ...ents of Directive 92 42 EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0087 Product Production certified by Notified Body 0086 Ref 86 BL 647 For GB IE only 5 2 Benchmark Commissioning Checklist 1 Please ensure that the installer has fully completed the Benchmark Checklist on the...

Страница 9: ...6 0 Notes 9 Baxi Heating UK Ltd 2009 ...

Страница 10: ...6 0 Notes 10 Baxi Heating UK Ltd 2009 ...

Страница 11: ...plier immediately Ventilate the property In GB Transco operate a 24 hour emergency service and the telephone number will be listed in your telephone directory Faulty boiler If it is known or suspected that a fault exists on the boiler it must not be used until the fault has been corrected by a competent person Warning ...

Страница 12: ...nty runs for 12 months from the date your product is installed What this warranty does not cover Repairs to boilers which haven t been installed and commissioned properly and as set out in the installation instructions this includes the need to flush the system effectively and add a suitable corrosion inhibitor Any damage caused by hard water scale deposits and or aggressive water resulting from c...

Отзывы: