7
0312_1601
Figure 4
0209_3022
Safety device Indicators-
activation
1
Summer-Winter-Reset selector
2
Flame indicator
3
Block indicator
4
Voltage presence indicator
If safety device activation is repeated contact the authorised Technical
Assistance Service.
NOTE*
Slow flashing: comes on approximately once every 2 seconds
Fast flashing: comes on approximately twice a second
Servicing instructions
To maintain efficient and safe operation of your boiler have it checked
by a Qualified Service Engineer at the end of every operating period.
Careful servicing will ensure economical operation of the system.
Do not clean the outer casing of the appliance with abrasive, aggressive
and/or easily flammable cleaners (i.e.: gasoline, alcohol, and so on).
Always isolate the electrical supply to the appliance before cleaning it
(see section Turning off the boiler on page 6).
Trouble
Gas block
No draught
No water in the heating circuit
or pump jammed
Probe broken
Safety thermostat tripping
Indicator
LED 2
LED 3
off
on
off
Fast flashing
off
Slow flashing
Slow flashing Slow flashing
on
Slow flashing
Reset
Set selector 1 to position R for at least 1 second.
Call your Authorised Service Centre
See circuit filling chapter
Call your Authorised Service Centre
Set selector 1 to position R for at least 1 second.