16.0 FAULT FINDING
50
Temperature sensors faulty.
Cold resistance approximately
10k
Ω
@ 25° C (DHW and CH sensors)
20k
Ω
@ 25° C (Flue sensor)
(resistance reduces with increase in temp.)
NO
E
Replace sensor
Gas at burner
Ensure gas is on and purged
Replace PCB
Replace gas valve
PCB - X3 connector is 230V AC
across terminals 1 & 2
YES
NO
NO
F
Replace PCB
G
Check and correct if necessary
1. Ignition electrode and lead
2. Electrode connection
3. Spark gap and position
voltage at PCB - X2 connector
is 230V AC across terminals 2,5
Check wiring
YES
NO
Replace igniter
YES
H
YES
1.
Ensure that the Hall Effect Sensor is in position.
Check the connection between the PCB - X400
connector terminals 3,6,7 and the electronic
sensor
Check the voltage between red wire and
blue wire is more than 5V DC
NO
Replace PCB
Check and correct the connection of
the tube between the venturi and
gas valve
Replace Hall
Effect Sensor
YES
1.
2.
4 ± 0.5
10 ± 1
7.5 ± 1
Electrode Position
Viewing Window
Burner
Publication No. 5116282