4.0
TECHNICAL DATA
10
Publication No. 5116282
4.2
Gold Combi 28 HE
Flue Terminal
Diameter
100mm
Dimensions
Projection
125mm
Outercase Dimensions
Casing Height
-
780mm
Overall Height Inc Flue
Elbow
-
965mm
Casing Width
-
450mm
Casing Depth
-
345mm
Weights
kg
Packaged Boiler Carton
56.5
Installation Lift Weight
45
Central Heating Primary Circuit
Pressures
bar
Safety Discharge
3
Max Operating
2.5
Min Operating
0.5
Recommended Operating Range
1-2
DHW Circuit
bar
Pressures
Max Operating
8
Min Operating
0.15
Flow Rates
l/min
DHW Flow Rate
@ 30
o
C Rise
13.3
DHW Flow Rate
@ 35
o
C Rise
11.5
Min Working
DHW Flow Rate
2
Pump
Available Head
See graph below
Expansion Vessel -
(For Central Heating
only. Integral with appliance)
bar
Min Pre-charge Pressure
0.5
litre
Max Capacity of
CH System
125
Primary Water Content
of Boiler (unpressurised)
2.5
Connections
copper tails
Gas Supply
-
22mm
Central Heating Flow
-
22mm
Central Heating Return
-
22mm
Cold Water Mains Inlet
-
15mm
DHW Flow
-
15mm
Pressure Relief Discharge -
15mm
Temperatures
C.H. Flow Temp
(adjustable)
25°C to 80°C
max
(± 5°C)
D.H.W. Flow Temp
(adjustable)
35°C to 60°C
max
(± 5°C)
dependent upon flow rate
NOx Class
5
0
200
400
600
800
1000
1200
0.5
1
1.5
2
2.5
3
3.5
4
Metre (wg)
Flow Rate (l/h)
Pump - Available Head
0
5
5.5
4.5
Clearances
Above Casing
200 mm Min
Below Casing
200 mm Min
Front
450 mm Min
(For Servicing)
Front
5 mm Min
(In Operation)
L.H. Side
5 mm Min
R.H. Side
5 mm Min
(In Operation)
Heat Input CH (Net)
Max
Min
kW
24.7
9
Heat Output CH (Non-Condensing)
Max
Min
kW
24
8.7
Electrical Supply
230V~ 50Hz
(Appliance must be connected to an
earthed supply)
Power Consumption
155W
Electrical Protection
IPX0D
Internal Fuse Rating
F2L
Appliance Category
CAT I
2H
Inlet Pressure
(Natural Gas - G20)
mbar
20
Injector
(Natural Gas - G20)
7.5mm
Appliance Type
C
13
C
33
Heat Output CH (Condensing)
Max
Min
kW
25.9
9.5
Heat Input DHW (Net)
Max
kW
28.9
Heat Output DHW
Max
kW
28
Max Gas Rate
(Natural Gas - G20)
(After 10 mins)
m
3
/h
3.1
This value is used in the UK Government’s Standard Assessment
Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by 0085.
SEDBUK Declaration For Gold 24 HE
The seasonal efficiency (SEDBUK) is 90.1%
Band A
Condensate Drain
To accept 21.5mm (
3
/
4
in) plastic waste pipe
Heat Input CH (Gross)
Max
Min
kW
27.4
10
Heat Input DHW (Gross)
Max
kW
32.1
External Fuse Rating
3A
Содержание Gold 24 HE
Страница 52: ...17 0 NOTES 52 Publication No 5116282 ...
Страница 53: ...53 17 0 NOTES Publication No 5116282 ...