EVD-2

ELECTRONIC VIBRATION DETECTOR

SYSTEM

INSTALLATION, OPERATION AND

INSTRUCTION  MANUAL

EVD-R

REMOTE PICKUP

RTA

(OPTIONAL)

EVD-M

CONTROLLER

Содержание EVD-2

Страница 1: ...3146 4161 800 325 3936 314 878 4321 FAX 314 878 7264 www pottersignal com Manual 5401042 Rev L 5 03 ALL SPECIFICATIONS SUBJECT TO REVISION EVD 2 ELECTRONIC VIBRATION DETECTOR SYSTEM INSTALLATION OPERATION AND INSTRUCTION MANUAL EVD R REMOTEPICKUP RTA OPTIONAL EVD M CONTROLLER ...

Страница 2: ...on or repair by unauthorized persons or if for any other reason POTTER determines that said product is not operating properly as a result of causes other than defective manufacture labeling or packaging THEAFORESAIDWARRANTYISEXPRESSLYMADEINLIEUOFANYOTHER WARRANTIES EXPRESSEDORIMPLIED ITBEINGUNDERSTOODTHATALLSUCH OTHERWARRANTIES EXPRESSEDORIMPLIED INCLUDINGTHEWARRANTIESOF MERCHANTABILITYANDFITNESSF...

Страница 3: ...NECTIONS 12 INSTALLATION 12 EVD WIRING WITH SAFE DETECTOR ZONEAND 24 HOURALARM ZONE 13 EVD WIRING WITH SAFE DETECTOR ZONE ONLY 14 SENSITIVITYADJUSTMENTS 15 ANALOG TEST POINT LEVELS 15 TESTING 16 RECOMMENDEDDETECTORLOCATIONS 17 DETERMININGTHE NUMBER OF DETECTORS FORASAFEAPPLICATION 18 DETERMININGTHE MAXIMUM LINEAR DISTANCE ONASAFE 19 TYPICALSAFE EXTERIOR DIMENSIONSAND MAXIMUM LINEAR DISTANCES 19 TY...

Страница 4: ...4 EVD 2 5401042 REVL 03 05 ...

Страница 5: ...13 0cm H x 8 3cm W x 3 0cm D Weight EVD M 0 64 lbs 0 29 kg EVD R 0 62 lbs 0 28 kg Enclosure Base Die cast aluminum Cover Stamped Steel 22 Gauge Power Input 9 0 VDC to 16 0 VDC 12 VDC Nominal Maximum 0 1 V ripple Typical Current Supply Voltage 12 0 VDC Normal Standby Condition 34 mA Alarm Condition 33 mA Tamper Condition 41 mA Each additional EVD R Remote Pickup adds approx 3 mA With model RTA conn...

Страница 6: ...iators that interface directly to the accessory terminals of the EVD M In addition to its remote test capability the EVD M provides a magnetically activated test switch that permits testing of the installation The EVD M contains a multi color LED to indicate system status This status LED indicates several states NOTES 1 If both an alarm condition and a tamper condition exist the status LED will in...

Страница 7: ...tact Normally Closed in NON TAMPER STATE 13 NC Alarm Relay Contact Normally Closed in NON ALARM STATE 14 COM Alarm Relay Contact Common 15 NO Alarm Relay Contact Normally Open in NON ALARM STATE NOTES 1 Observe polarity of power supply connections Application of voltages greater than 18 VDC may result in damage to unit 2 If EVD R remote pickups are installed remove the factory installed 10K Ohm 1 ...

Страница 8: ...ller A cover tamper and a back tamper protect the EVD R from cover removal or prying If either of these tampers activate or the tamper from the safe contact interface activates the EVD R will signal a tamper condition to the EVD M During a tamper condition the EVD R network is fully capable of signaling alarm conditions to the EVD M control ler If more than five EVD R remote pickups simultaneously...

Страница 9: ...k Connection 10 SHIELD Output Shield Connection to IN SHIELD of Next Pickup or EVD M SHIELD Connection 11 SIGNAL Output Sensor Signal to IN SIGNAL of Next Pickup or EVD M SIGNAL Connection 12 REF Output Reference to IN REF of Next Pickup or EVD M REF Connection NOTES 1 Remove all factory installed 10K Ohm 1 end of line resistors from pins 1 2 and pins 2 3 of all EVD R s except the LAST EVD R remot...

Страница 10: ...10 EVD 2 5401042 REVL 03 05 Figure 4 RECOMMENDED WIRING EVD 2 SYSTEM Shown with 2 additional EVD R remote pickups EVD R EVD M EVD R EVD R ...

Страница 11: ...rom all other EVD R s and the EVD M 7 Connections to dry contacts from any UL listed safe contact Last EVD R is the preferred unit for connections to the safe contact However all EVD R remote pickups accept safe contact wiring Additional safe contacts can be wired into other EVD R remote pickups the EVD M or a UL listed tampered junction box If the safe contact is wired into the EVD M use the alte...

Страница 12: ... installed do not remove the end of line resistors on the EVD M 2 Refer to Figure 5a for connection of a remote test annunciator RTA and or a UL listed central station test unit if applicable 3 Refer to Figure 4 for the connection of UL listed dry contacts if applicable 4 Verify proper installation of the end of line resistors Refer to Figures 2b and 4 for systems with remote pickups 5 Wire contro...

Страница 13: ...042 REVL 03 05 RECOMMENDED CONTROL PANEL WIRING WITH SAFE DETECTOR ZONE AND 24 HOUR ALARM ZONE High security B cable and connections to 24 hr zone as shown are required for UL safe compatible installations Figure 5b ...

Страница 14: ...14 EVD 2 5401042 REVL 03 05 RECOMMENDED CONTROL PANEL WIRING WITH SAFE DETECTOR ZONE ONLY 4 Conductor Shielded Cable Required Figure 5c ...

Страница 15: ... indicated by the status LED turning RED must occur Be sure the scraping generates a test point voltage greater than the minimum constant noise level shown in Table 3 Adjust sensitivity settings to the minimum needed to achieve desired level of response NOTE Extreme care should be exercised so that the protected surfaces are not marred or damaged while performing simulated attack tests A voltmeter...

Страница 16: ...gnal which causes the EVD M to signal an alarm condition NOTE Always test unit prior to placing unit into service Unit must be tested at least once a year SAFECONSTRUCTIONREQUIREMENTS Table 4 Maximum Linear Distances from Detector to Any Point on the Pro tected Surface n o i t c u r t s n o C e f a S r a e n i L m u m i x a M r o t c e t e D m o r f e c n a t s i D t n i o P y n A o t m u m i n i ...

Страница 17: ...d for a single detector installation Mount the second detector on the opposite side of the safe at the same height and with the same front edge offset as the first detector Safes with double doors that conform to the dimensional requirements for the use of one or two detectors should be protected in this fashion Figure 7 shows the recommended detector locations of a safe application requiring two ...

Страница 18: ...with a larger distance than that shown in Table 5 consult Potter s technical support for assistance Table 5 m u m i x a M e c n a t s i D r a e n i L t n i o P y n A o t r o t c e t e D m o r f f o s e c a f r u S d e t c e t o r P n o s e f a S l e e t S m u m i x a M e c n a t s i D r a e n i L t n i o P y n A o t r o t c e t e D m o r f f o s e c a f r u S e t c e t o r P n o s e f a S e t i s ...

Страница 19: ...r two dimensions the safe may not follow this rule In those cases contact Potter s technical support for assistance Table 6 lists some common safe dimensions and their maximum linear distances when detectors are installed in recommended locations Table 6 Typical Safe Exterior Dimensions and Maximum Linear Distances t h g i e H s e h c n I h t d i W s e h c n I h t p e D s e h c n I e m u l o V t f...

Страница 20: ...s is less than 1 1 2 inches 4 Wire detectors and door contacts as shown in Figures 4 and 5a 5 Listed power supply or control unit must provide at least 4 hours of standby power for mercantile alarms and 72 hours of standby power for bank vault alarms EVD 2 WALL PROTECTION Figure 9 shows the rectangular areas of 100 coverage when detectors are installed adjacent to one another The detector spacing ...

Страница 21: ... S k c i h T 4 1 m u m i n i M 0 8 3 1 1 x 3 1 1 9 3 1 x 8 5 2 1 x 0 1 6 5 x 5 1 f l a H 0 5 1 2 1 2 x 2 1 2 9 8 2 x 8 3 8 2 x 0 1 6 2 x 5 1 4 2 2 x 0 2 m u m i x a M 0 0 2 3 8 2 x 3 8 2 2 9 3 x 8 7 8 3 x 0 1 1 7 3 x 5 1 6 4 3 x 0 2 e t e r c n o C c i h t i l o n o M k c i h T 6 t s a e L t a m u m i n i M 0 6 1 6 2 2 x 6 2 2 0 1 3 x 8 4 0 3 x 0 1 3 8 2 x 5 1 0 5 2 x 0 2 t a k c o l B e t e r c n...

Страница 22: ...22 EVD 2 5401042 REVL 03 05 ALLDIMENSIONSININCHES Figure 11 EVD M OR EVD R MOUNTING TEMPLATE ...